No. | Test item | Criterion |
1 | Voltage | Charging voltage | DC:16.8V CC/CV |
Balance voltage for single cell | 4.20±0.025V |
2 | Current | Balance current for single cell | 42±5mA |
Current consumption | ≤20μA |
Maximal continuous charging current | 40A |
Maximal continuous Discharging current | 40A |
3 | Over charge Protection | Over charge detection voltage for single cell | 4.25±0.025V |
Over charge detection delay time | 0.5S—1.5S |
Over charge release voltage for single cell | 4.05±0.05V |
4 | Over discharge protection | Over discharge detection voltage for single cell | 2.50±0.062V |
Over discharge detection delay time | 10mS—150mS |
Over discharge release voltage for single cell | 3.00±0.062V |
5 | Over current protection | Over current detection voltage | 0.62V |
Over current detection current | 120±20A |
Detection delay time | 5ms—20ms |
Release condition | Cut load |
6 | Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-500us |
Release condition | Cut load |
7 | Resistance | Protection circuitry(MOSFET) | ≤20mΩ |
8 | Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ |