Place of Origin: | Zhejiang |
---|
Location: | Shanghai, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Seawater RO Plant, Brackish Water Reverse Osmosis Systems, Waste Water Treatment Plant |
Model No.: | BWRO-50 |
---|
50 m3 / day Brackish Water Reverse Osmosis Systems for potable water With ORP controller
1. Specifications:
Technical data |
Feed TDS |
1000-10000 ppm |
Feed temperature |
2-40 |
|
Feed PH |
3-11 |
|
Operation pressure |
1.5-4 Mpa |
|
Desalination rate |
>98% |
|
Permeate water salinaty |
<500 mg/L |
|
Capacity |
120-1500 m3/day |
|
Electricity |
380V/50HZ/3PH, other volt upon client |
|
Tonnage water consumption |
2 Kwh/T |
|
Control |
PLC and touch screen |
|
Configuration |
Containerized |
|
Instrument |
Flow meter, TDS, pressure gauge |
|
Standard Features |
Powder coated carbon steel frame |
|
Heavy duty 5 micron cartridge prefilter |
||
Chemical dosing |
||
Anti corrosion resistant stainless steel pumps |
||
PLC based controller panel |
||
Liquid filled 316L pressure gauges |
||
Product and reject flow meters |
||
Spriral wound RO membranes |
||
FRP membrane pressure housings up to 1200 psi |
||
Low and high pressure switch |
||
Permeate TDS monitor |
||
Stainless steel high pressure piping |
||
Optional |
PH/ORP controller |
|
Clean-in-place CIP skid |
||
Multimedia prefilter |
||
Activated carbon prefilter |
||
Ozonation / UV sterilization systems |
2. Description:
Brackish water reverse osmosis equipment is tasked with purifying water and eliminating salts and other contaminates from many different impure sources. They have the power of blocking bacteria, particles, sugars, proteins, dyes, and other impurities that encompass a molecular weight of more than 150-250 dalton.
Industrial reverse osmosis machines include multimedia prefilters, a water softener, the reverse-osmosis unit with semi-permeable membranes, and an optional UV sterilizer post treatment. These machines apply the technology of reverse osmosis by transporting feed water through multimedia prefilters to take out huge particles and suspended solids. Then the water is transported into a water softener to remove hardness that may cause damage to the membranes within the machine. These pretreatments have the capability of removing hardness, chlorine, odors, color, iron, and sulfur. The water then continues into the reverse osmosis machine where a high pressure pump applies extreme pressure to the highly concentrated solution, separating the remaining salts, minerals, and impurities that the pre-filters couldn’t catch. Fresh, potable water comes out from the low pressure end of the membrane while salts, minerals, and other impurities are discharged into a drain on the other end. Lastly, the water is passed through a UV sterilizer to kill any bacteria and microbes that still exist in the water.
Model selections
Model | Capacity | Operation Pressure | Voltage | Frequency |
Electricity consump |
Dimension | Type | ||
GPD | L/HR | Pretreat | Membrane | V | HZ | CM | |||
SWRO-600 | 600 | 100 | 0.1-0.3 | 1.5-4Mpa | 220/380 | 50 or 60 HZ | 11Kwh/T | 58x44x160 | Vertical |
SWRO-1500 | 1500 | 250 | 0.1-0.3 | 1.5-4Mpa | 220/380 | 50 or 60 HZ | 8Kwh/T | 65x44x160 | Vertical |
SWRO-3000 | 3000 |
|