1. Design Criteria of Steel Tower
1.1 Basic wind speed=110KMPH (3 second gust)
1.2 Exposure Category C and Topographic Category crest height
1.3 Design Code: ANSI/TIA/EIA-222-G Latest
1.4 Max Antenna Load 22m2
2. Fabrication
2.1 Prototype assembly of each new tower type should be done before mass production.
2.2 Hot-dip galvanization in accordance with ISO1461-2009 and ASTM A123.
3. Steel Material
3.1 Legs Steel will be high tensile steel like Q420/Q345 with yield strength is 420/345MPa.
3.2 Others Steel will be middle steel like Q235 with yield strength is 235MPa.
3.3 Bolts will be follow ISO 898 grade 6.8/8.8
4. Quality and Quantity
4.1 We have been providing world top class design, engineering and manufacturing for telecommunication tower and related infrastructure materials worldwide and gaining a very good reputation in this field during past decades.
4.2 Our professional team have more than 80 years experience in this industry field. We are paying a lot of attention for quality and quantity issues during each procedures in order to avoid any possible mistakes which help our clients a lot.
4.3 SGS or BV physical pre-inspection are acceptable
Tower Height | 50 meters |
location | many countries |
Client | turnkey solution |
Lifetime | 30 years |
Foundation | 150 KPa soil bear capability |
Goods Description | hot dip galvanization Self-supported Angle Steel Tower |
Component | Steel Tower with platform,climbing ladder with safety cage,cable ladder,HD bolts and foundation template, bolts and nuts, antenna brackets, working platform and rest platform |
Accessories | Paint kits, Lightning & earthing System, Fall arrest system, Navigation light, Generators, Security room, Canopy, Shelter and Palisade Fencing
|