Place of Origin: | Zhejiang |
---|
Location: | Hangzhou, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Air Separation Plant, Acetylene Plant, Compressed Gas Cylinder |
Model No.: | KDONAR-1000Y/1000/35Y |
---|
99.6% Air Separation Plant KDONAR-1000Y/1000/35Y Industrial Oxygen Plant With Low Energy
Plant design basis (need buyer’s confirmation)
Design point of Atmosphere |
|
Ø Atmosphere pressure |
101.3kPa(A) |
Ø Atmosphere tempt. |
30 |
Ø Relative humidity |
75% |
Ø O2 contained in air |
20.95% O2 |
Atmosphere tempt. |
|
Ø Annual average tempt. |
18.4 |
Ø Max. Tempt. |
40 |
Ø Min. Tempt. |
-1.8 |
Ø Summer average tempt. |
30 |
Ø Winter average tempt. |
7.5 |
Earthquake degree: |
6 degree |
Altitude: |
50m |
Impurity in air |
|
Ø CO2 |
≤350 ppm |
Ø SO2 |
≤0.44 mg/m3 |
Ø H2S |
≤2.3 mg/ m3 |
Ø CH4 |
≤5.2mg/ m3 |
Ø C2H2 |
≤0.03 ppm |
Ø CnHm(excluding C2H2) |
≤5 ppm |
Ø Mechanical impurity |
≤10mg/m3 |
Recycle water |
|
Ø Inlet tempt. |
30 |
Ø Inlet pressure |
0.4 MPa(G) |
Ø Max pressure drop |
0.2 MPa(G) |
Ø Max tempt. rising |
10 |
Ø Turbidity of cooling water |
12 mg/L |
Ø PH value |
7.2 |
Ø Rigidity |
2.5 |
Ø Fouling factor |
0.0004 m2 hºC/ K.W |
Ø Total water consumption |
260T/h |
Power condition |
|
Ø High voltage power |
10,000V±5% 3 phases 3 ways |
Ø Low voltage power |
380V/220V±5% AC 3 phases 4 ways |
Ø Frequency |
50±0.5HZ |
Ø Power amount |
2200KW |
Instrument gas ( used for starting) |
|
Ø Pressure |
0.5 MPa(G) |
Ø Tempt. |
≤30 |
Ø Dew point |
-40 |
Ø Flow |
300m3/h |
Ø Requirement |
oil free |
Annex 2. Main parameter
Capacity and purity(out of cold box): |
|||
Designed working condition 1 |
|||
Medium |
capacity (Nm3/h) |
purity |
pressure(MpaG) |
Luquid O2 |
1,050 |
≥99.6%O2 |
0.16 |
N2 |
1000 |
≤3ppmO2 |
0.008 |
Liquid argon |
35 |
≤2ppmO2,≤3ppmN2 |
0.16 |
Designed working condition |
|||
|