Medical Fingertip Pulse Oximeter Blood Oxygen Monitor For Home

Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Liquid Crystal Thermometer, LCD Thermometer Strip, Color Changing Thermometer

Product Detail

Model No.: EC-P60B

Product Description

Medical Fingertip Pulse Oximeter Blood Oxygen Monitor For Home 

 

 

Configuration:

 

Function Configuration
Display OLED
Spo2 parameter measurement Y
Pulse rate parameter measurement Y
PI parameter measurement Sel
Pulse waveform display Y
Bar graph display Y
Pulse beat show function Y
Four direction screen overturn function Y
Screen automatic overturn function Sel
Automatic power-off function Y
Abnormal parameter value alarm function with the measurement value sparkling Y
Abnormal parameter value alarm function with the sound Sel
Abnormal parameter value alarm function with the UI alarm string rolling Sel
Motion or light disturb alarm function with the UI alarm string rolling Sel
Arrhythmia indication function with the UI indication string rolling Sel
Low-power UI icon indication Y
Low-power UI character string alarm function Sel
Alarm setting function Sel
Pulse beat sound Y
Pulse sound On/Off function Y

 

 

 

Attention : "Y" expresses the function item is the standard configuration , and the "Sel" expresses the function item will be configured according to the users’ demand .

 

 

1.2 Users : Pediatric , adult.

 

1.3 Major applications and scope

  • Is used in measuring the pulse oxygen saturation and pulse rate through finger ;
  • Is fit for family, hospital, oxygen bar, community healthcare, physical care in sports(It can be used
  • before or after doing sports and it is not recommended to use the device during the process of having sport) and etc ;
  • Not recommended to be used for monitoring the patients for a long time without any rest ;
  • Do NOT use the device in an MR/CT environment, in an exprosive atmosphere, or on infant or neonatal patient .
  • High temperature or high pressure steam disinfection for the oximeter is not permittedDo not have the oximeter immerged in liquid ;
  • Operation of this device below the minimum amplitude of 0.4% modulation may cause inaccurate results
  • The device is designed to measure the percentage of arterial oxygen saturation of functional hemoglobin Factors that may degrade pulse oximeter performance or affect the accuracy of the measurement include the following :

Do not apply the pulse oximiter on the same arm as a blood pressure cuff, arterial catheter or infusion line(s)(IVs) .

Excessive light, such as sunlight or direct home lighting . Moisture in the device

Finger is outside recommended size range

Poor pulse quality

Venous pulsations