Pure Sine Wave 48VDC 3KW Built-in AVR On-Grid Solar Inverter with MPPT Charger
Built-in AVR On-Grid Solar Inverter Description:
1. High performance string inverters
2. Wide PV input voltage range
3. Rapid MPPT tracking technology
4, Superioor PV energy harvest
5. Transformeriess design with higher operation efficiency
6. Excellent natural thermal design
7. High overload capability under most ambient conditions
8. Easy and affordable to install
9. Lightweight and compact size,Includes a lightweight portable bracket simplifying installation
10. Firm IP65 inverter enclosure allows outdoor application
11. Full data display and communications
12. Customization LCD display all the inverter operation message
13. Bright LED indicators imply system status at a glance PC xoftware for remote monitoring and system troubleshooting
14. High speed RS232,RS485 communications port.
15. First SD card to update the inverter firmware technology and storage operating data technology
Specifications:
Model Specification |
PTS3000 |
PTS2500 |
PTS-2000 |
PTS1600 |
PTS1000 |
Input data |
|
||||
Max. DC power |
3200W |
2800W |
2300W |
1900W |
1300W |
Max. DC voltage |
500V |
500V |
500V |
500V |
500V |
Start voltage |
100V |
100V |
100V |
100V |
70V |
DC nominal voltage |
360V |
360V |
360V |
360V |
360V |
PV voltage range |
100V-500V |
100V-500V |
100V-500V |
100V-500V |
70V-500V |
MPP voltage range |
120V-450V |
120V-450V |
120V-450V |
120V-450V |
100V-450V |
Max. input current of tracker |
15A |
12A |
12A |
10A |
10A |
Number of MPP trackers/strings per MPP tracker |
1/2 |
1/2 |
1/2 |
1/1 |
1/1 |
Output (AC) |
|
||||
Nominal AC output power |
3000W |
2500W |
2000W |
1600W |
1000W |
Max. AC apparent power |
3000VA |
2500VA |
2000VA |
1600VA |
1000VA |
Max. output current |
15A |
12.5A |
10A |
8A |
5A |
AC nominal voltage; range |
220V/230V/240V; 180Vac-280Vac |
220V/230V/240V; 180Vac-280Vac |
220V/230V/240V; 180Vac-280Vac |
220V/230V/240V; 180Vac-280Vac |
220V/230V/240V; 180Vac-280Vac |
AC grid frequency; range |
50,60H;±5 Hz |
50,60H;±5 Hz |
50,60H;±5 Hz |
50,60H;±5 Hz |
50,60H;±5 Hz |
Phase factor at rate power |
1 |
1 |
1 |
1 |
1 |
THDI |
<3% |
<3% |
<3% |
<3% |
<3% |
AC connection |
Single phase |
Single phase |
Single phase |
Single phase |
Single phase |
Efficiency |
|
||||
Max. efficiency |
97% |
97% |
97% |
97% |
97% |
Euro - eta |
96.50% |
96.50% |
|