Min. Order: | 5 Piece/Pieces |
---|---|
Trade Term: | FOB,CFR,CIF,CIP,EXW |
Payment Terms: | L/C, T/T, WU, Money Gram |
Supply Ability: | 50, 000PCS/Month |
Place of Origin: | Guangdong |
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | UPS, Inverter, Battery, Controller, Solar Power |
Model No.: | Hanker Power Star Series 1KW-12KW |
---|---|
Means of Transport: | Ocean, Air |
Type: | DC/AC Inverters |
Output Type: | Single |
Output Power: | >500W |
Brand Name: | UPSEN |
Input Voltage: | 12/24/48V |
Output Voltage: | 100-110-120Vac / 220-230-240Vac |
Warranty: | 12 Months |
Sample: | Yes |
Charger Breaker Rating: | 10A/15A/20A/30A/40A |
Transformer Inside: | Copper Transformer |
Production Capacity: | 50, 000PCS/Month |
Packing: | Cartons & Wooden Pallet |
Delivery Date: | 7-15 Days |
3000W 4000W DC12V 24V 48V Single Phase Off Grid Inverter
Pure Sine Wave Inverter Charger Hanker Power Star Series 1KW-12KW (1ph in/1ph out)
HP Series Pure Sine Wave Inverter is a combination of an inverter, charger, solar power and Auto-transfer switch into one complete system . It is packed with unique features and it is one of the most advanced inverter/chargers in the market today.
Feature of HP Series Inverter & Charger
1:Input and output are completely independent
2:Output AVR: stabilized AC voltage RMS( optional)
3:Pure sine wave output, available for sensitive load
4:imported intelligent fan, temperature control design
5:Solar power mode and Grid power mode, can be free choose
6:Feature-rich, stable and reliable, with high cost performance
7:Super efficient, DC to AC conversion, minimizing charging losses
8:High efficiency design & power saving mode to conserve energy
9:Smart battery charger design for optimized battery performance
10:Small, light and artistic, benefited from adopting the SMD paster technology
11:Be able to recharge the batteries automatically when the inverter is off
12:High frequency design, higher transfer efficiency, low standby power loss, long standby time
13:Intelligent air cooling design,Effective solution to the system cooling, improve the fficiency of the system
Application
Emergency lighting equipment,telemeter equipment,Data Processing Center,
National Defense System,Electronic Cash Registers,Robots, Network Rooms,Education System,Medical Equipment,Financial System,Securities System etc.
Technical Specification | |||||||||||
Model | HP1K | HP1.5K | HP2K | HP3K | HP4K | HP5K | HP6K | HP8K | HP10K | HP12K | |
Inverter Output | Continuous Output Power | 1.0KW | 1.5KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW |
Surge Rating(20s) | 3.0KW | 4.5KW | 6.0KW | 9.0KW | 12.0KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW | |
Output Waveform | Pure Sine wave/Same as input(Bypass Mode) | ||||||||||
Nominal Efficiency | >88%(Peak) | ||||||||||
Line Mode Efficiency | >95% | ||||||||||
Power Factor | 0.9-1.0 | ||||||||||
Nominal Output Voltage rms | 100-110-120Vac / 220-230-240Vac | ||||||||||
Output Voltage Regulation | ±10% RMS | ||||||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | ||||||||||
Short Circuit Protection | Yes( 1sec after fault ) | ||||||||||
Typical transfer Time | 10ms(Max) | ||||||||||
THD | < 10% | ||||||||||
DC Input | Nominal Input Voltage | 12.0Vdc | |||||||||
( *2 for 24Vdc, *4 for 48Vdc) | |||||||||||
Minimum Start Voltage | 10.0Vdc | ||||||||||
Low Battery Alarm | 10.5Vdc / 11.0Vdc | ||||||||||
Low Battery Trip | 10.0Vdc / 10.5Vdc | ||||||||||
High Voltage Alarm | 16.0Vdc | ||||||||||
Low Battery voltage recover | 15.5Vdc | ||||||||||
Idle Consumption -Search Mode | < 25 W when Power Saver On | ||||||||||
Charger | Output Voltage | Depends on battery type | |||||||||
Charger Breaker Rating | 10A | 15A | 20A | 20A | 20A | 30A | 30A | 40A | 40A | 40A | |
Max Charge Power Rate | 1/3 Rating Power | ||||||||||
Battery Initial Voltage for Start Up | 10-15.7V for 12V( *2 for 24V, *4 for 48V) | ||||||||||
Over Charge Protection Shutdown | 15.7V for 12V (*2 for 24V, *4 for 48V) | ||||||||||
Remote Control | Yes(Optional) | ||||||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | |||||||||
Nominal Voltage | 110Vac | 120Vac | 220Vac | 230Vac | |||||||
Max Input AC Voltage | 150VAC For 120Vac LV Mode;300VAC For 230Vac HV Mode; | ||||||||||
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | ||||||||||
Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | ||||||||||
High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | ||||||||||
Overload protection (SMPS load) | Circuit breaker | ||||||||||
Output Short circuit protection | Circuit breaker | ||||||||||
Bypass breaker rating | 10A | 15A | 20A | 30A | 40A | 40A | 40A | 50A | 63A | 63A | |
Transfer switch rating | 30amp for UL & TUV | 40amp for UL | 80amp for UL | ||||||||
Bypass without battery connected | Yes (Optional) | ||||||||||
Max bypass current | 30amp | 40amp | 80amp | ||||||||
Solar Charger (Optional) | Rated Voltage | 12Vdc / 24Vdc / 48Vdc | |||||||||
Solar Input Voltage Range | 15-30Vdc / 30-55Vdc / 55-100Vdc | ||||||||||
Rated Charge Current | 40 ~ 60A | ||||||||||
Rated Output Current | 15A | ||||||||||
Self Consumption | < 10mA | ||||||||||
Bulk Charge | 14.5V(default) | (*2 for 24Vdc, *4 for 48Vdc) | |||||||||
Floating Charge | 13.5V(default) | ||||||||||
Equalization Charge | 14.0V(default) | ||||||||||
Over Charge Disconnection | 14.8V | ||||||||||
Over Charge Recovery | 13.6V | ||||||||||
Over Discharge Disconnection | 10.8 V(default) | ||||||||||
Over Discharge Reconnection | 12.3V | ||||||||||
Temperature Compensation | -13.2mV/°C | ||||||||||
Ambient Temperature | 0 ~ 40°C(Full load) 40 ~ 60°C(Derating) | ||||||||||
Mechanical Spec | Mounting | Wall Mount | |||||||||
Inverter Dimensions(L*W*H) | 388*415*200mm | 488*415*200mm | 588*415*200mm | ||||||||
Inverter Weight(Solar Chg)KG | 21+2.5 | 22+2.5 | 23+2.5 | 27+2.5 | 38+2.5 | 48+2.5 | 49+2.5 | 60+2.5 | 66+2.5 | 70+2.5 | |
Shipping Dimensions(L*W*H) | 550*520*310mm | 650*520*310mm | 750*520*310mm | ||||||||
Shipping Weight (Solar Chg)KG | 23+2.5 | 24+2.5 | 25+2.5 | 29+2.5 | 40+2.5 | 50+2.5 | 51+2.5 | 62+2.5 | 68+2.5 | 72+2.5 | |
Display | Status LEDs / Status LEDs+LCD | ||||||||||
Standard Warranty | 3 Years (Optional) |