user login

Insulated Copper Overhead Crane Conductor System Crane Bus Bar

Place of Origin: Zhejiang

Company Profile

Location: Hangzhou, Zhejiang, China (Mainland)
Business Type: Manufacturer
Main Products: C Track Festoon System, Electric Chain Hoist, Flat Electrical Cable

Product Detail

Model No.: HFP

Product Description

Specifications

 

1. Crane Conductor System-Enclosed Conductor Rails
2. Good quality self-extinguishing shell
3. Flexible usage
 

 

Crane Conductor System-Enclosed Conductor Rails, Similar with Wampfler Boxline 0842, Conductor Rail, Powerails, Conductor Bar, Bus Bar, DSL System, Conductor Trolley Bar, IGS

 

 

Application

 

The ranges of applications of HFP Power Rail Enclosed Conductor System

  1. Overhead and elongated tracks for cranes. 
  2. Electric hoists, electric tools, stacking systems.
  3. Electric tools
  4. Other applications for supplying power to moving power load.

 Design features

 

 Compact arrangement, corrosion resistance and simple assembly are its essential features.

 

Housing

Color green, PVC housing for 4 conductors. Standard section 4 m.

Other sections are available.

The ground conductor is identified by international color code.

Phase reversing prevented by design of the collector and housing.

 

Current collectors

The current collectors are made of re-inforced polyester fiberglass,for high strength and light weight.

Spring loaded carbon brushes maintain uniform contact.

Connecting cables and hinged or flexible towing arms included.

Double Current collectors for transfer applications and higher amperage.

 

Couplings

Through PVC joint caps.

 

Feed Sets

Line feeds or end feeds. 

 

End caps

The open ends of the powerail are closed by end caps for HFP. 

 

Hangers

Standard brackets for powerail attachment to crane girders are available.

Powerail with sliding and fixpoint hangers.

Standard distance between suspension points for indoor and outdoor installations:1200mm.

 

Expansion during temperature fluctuation 

The Expansion sections are required to compensate the different expansions between copper conductors and steel-or concrete structures,in varying temperatures without interrupting electrial power.

 

Anti-condensation sections

These sections are used for transfer of the Powerail to outdoor areas to avoid condensation.

 

Sectionalizing

Available as air gap version (5mm),where the collector carbon bridges the gap,e.g.for mains.

 

Technical Parameters

 

Model

Pole No.

Cross section

Max. current

Leakage-distance

Max. voltage

Resistance

Dimensions (H * W)

Weight

HFP56-4-8/35

4

8

35

35

600

1.944

73*56

2.09

HFP56-4-10/50

4

10

50

35

600

1.656

73*56

2.16

HFP56-4-12/65

4

12

65

35

600

1.321

73*56

2.23

HFP56-4-15/80

4

15

80

35

600

1.137

73*56

2.3

HFP56-4-20/100

4

20

100

33

600

Post Buying Request