Dual Vehicle Inductive Loop Detector For Parking Access Control System

Place of Origin: Zhejiang

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Traffic Loop Detector, Single Channel Loop Detector, Magnetic Loop Detector

Product Detail

Model No.: NBLD-100

Product Description

Dual Vehicle Traffic Inductive Loop Detector For Parking Access Control System

 

 

Description:

 

Loop detectors in recent years have become a popular tool having innumerable applications in policing, right from surveillance operations to traffic control. Automation of gates and doors has become a popular usage of the loop detector.

 

 

Features :

 

1. Indicates and Switch:

 

Power Led: RED power LED indicates “Power ON”


CH1 Detecting Led:Continuously On: Indicates vehicle detection.
Blinking slowly: Indicates loop is short circuit or the number of twists after the loop is not enough.
Blinking fast: Indicates loop is open circuit or too many twists after the loop.


CH2 Detecting Led:Continuously On: Indicates vehicle detection.
Blinking slowly: Indicates loop is short circuit or the number of twists after the loop is not enough.
Blinking fast: Indicates loop is open circuit or too many twists after the loop.

 

2. Sensitivity Selection:

 

Sensitivity and frequency of the loop can be adjusted by 7-way dip switch and 10-way dip switch setting.
User can select 8 different setting by changing the setting of the dip-switch to different modes as in the
dip-switch setting tables below. Dip switch 6, 7 and 8 for CH1 sensitivity selection with 0.8 being the least sensitive and 0.015 being the most sensitive. Dip switch 3, 4 and 5 for CH2 sensitivity selection
with 0.8 being the least sensitive and 0.015 being the most sensitive.

 

Specifications:

 

Self-turning range 20-2000μH
Response Times 10-90MS
Sensitivity 16 way selectable levels
Visual Indications Power LED-Red, Channel LED-Green
Frequency Four step switch, selectable 20-80KHz
Relay Output Presence Relay/Fault Relay
Power Requirements 110-240VAC (48 to 62Hz)
Fault Output Blinks slowly, Blinks faster
Reset

Reset by push button on front of enclosure

Product size 92*76*42mm
Label Language English
Connections 11-pin Submagnal
Storage Temperature -40 to 80 Celsius degree
Normal Working Temperature -40 to 70 Celsius degree

 

 

Applications:

 

Traffic Control Application

Vehicle Counting

Toll Systems

Traffic Analysis

Parking Control Application

 

 

Competitive Advantage:

 

Self-turning range: 20-2000μH

Response Times: Turn-on 10-90MS

                Turn-off 10-90MS

Sensitivity:       16 way selectable                                        

                Highest 0.010% DL/L                                     

                Lowest 2.56% DL/L

 

 FAQ:

 

Q1: If the detector is not working?

A1: Press reset

Q2: If red led indicator is not fully lit?

A2: Check for power supply

Q3: If green led indicator blinks slowly?

A3: It maybe because the loop is short circuit or the no: of turns is not enough.

Q4: If green led indicator blinks slowly?

A4: It maybe because the loop is open or the no: of turns is too many.

Q5: If no: of turns is not enough?

A5: Lower the frequency (if the frequency is still too high, you must add more turns).

Q6: If no: of turns is too many?

A6: Higher the frequency (if the frequency is still too low, you must remove some turns). 

 

Inductive loop detector picture:

 

 

Post Buying Request