230 VAC Black Vehicle Loop Detector 20uh - 2000uh for Car Parking

Place of Origin: Zhejiang

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Traffic Loop Detector, Single Channel Loop Detector, Magnetic Loop Detector

Product Detail

Model No.: LD-100-W

Product Description

 

230 VAC Black Vehicle Loop Detector 20uh - 2000uh for Car Parking
 
 

Description:

 

The loop consists of several loops of wire and consideration

should be giving to the loop sensitivity when installing on different surfaces. Setting the correct sensitivity allows the loop to operate with maximum detection (16 levels via a trimpot). When detection occurs, the detector energises 2 relays for the output (each can be configured individually). This energising of the relay can be configured into different modes, by selecting the respective dip switch.


The NBT-ILD™ vehicle loop detector is compatible with most gate operators. The ULT-MVP may be used in Center, Safety and Exit loop positions.Fifteen sensitivity settings allow for fine adjustment of the detection level.

 

Sensitivity Selection
       Sensitivity of the loop can be adjusted by the trimpot labeled “Sensitivity”. User can select 16 different setting by turning the trimpot with 0 being the least sensitive and “F” being the most sensitive.

Loop detectors in recent years have become a popular tool having innumerable applications in policing, right from surveillance operations to traffic control. Automation of gates and doors has become a popular usage of the loop detector.


Specifications:

Technical Parameter for single channel vehicle detector

Loop Inductance

20-2000μH(Q Factor >5)

Response Times

10-90MS

Sensitivity

0-F,16 levels

Visual Indications

Power LED-Red, Channel LED-Green

ABS

automatic sensitivity boost

Relay time

0,2,4,8,10,15,20,30 seconds

Loop frequency

4 setting(low,Med-low,Med-Hi,High)

Operating Current

20mA standby

Housing Color

Black,White,OEM/ODM

Weight

0.18KG

Label Language

English or OEM/ODM

Connections

Socket mount-11pin male(JEDEC B11-88)

Storage Temperature

 -40 to 80 Celsius degree

Normal Working Temperature

 -40 to 70 Celsius degree

 

 

Detector position and installation
1. Install the detector in a weatherproof housing.
2. The detector should be as close to the sensing loop as possible.
3. The detector should always be installed away from strong magnetic fields.
4. Avoid running high voltage wires near the loop detectors.
5. Do not install the detector on vibrating objects.
6. When the control box is installed within 10 metres of the loop, normal wires can be used to
    connect the control box to the loop. More than 10 metres requires the use of a 2 core shielded cable.       Do not exceed 30 metres distance between control box and loop.
 
 Troubleshooting

Symptoms

Solution

If the detector is not working

Press reset

If red led indicator is not fully lit

Check for power supply


If green led
indicator:

Blinks slowly

It maybe because the loop is short circuit or the no: of turns is not enough.

Blinks faster

It maybe because the loop is open or the no: of turns is too many.

If no: of turns is not enough

Lower the frequency (if the frequency is still too high, you must add more turns).

If no: of turns is too many

Higher the frequency (if the frequency is still too low, you must remove some turns).


 Application:traffic vehicle detection for weighting system


    
Ordering Information:
LD-100  single channel, boxed, 1 type 11pin connects 100-240VAC(EU standard)
LD-102  single channel, boxed, 1 type 11pin connects 12-24VADC(EU standard)
LD-105  single channel, boxed, 2 type 11pin connects 100-240VAC(USA standard)
LD-106  single channel, boxed, 2 type 11pin connects 12-24VADC(USA standard)

 

Tag:traffic detectors,vehicle  detectors. 

Post Buying Request