Product Electric Parameters
|
Input specification
|
Input voltage
|
AC110V---220V
|
Input frequency
|
50-60Hz
|
Input surge
|
20A@120VAC
|
Output specification
|
Output voltage can be adjusted
|
±10%
|
Start-up time
|
1S(input230V Io=100%)
|
keep time
|
20mS (input230V,Io=100%)
|
Voltage regulation
|
(Full load) 0.5%
|
Protection function
|
Overload protection
|
105% - 150% rated power, automatic recovery
|
Over-voltage protection
|
105% - 150% of the rated voltage
|
Insulation intensity
|
Input---output
|
1500VAC/1min
|
Input---ground
|
1500VAC/1min
|
Input---ground
|
500VAC/1min
|
Safety standards
|
According with GB4943, UL60950-1,EN60950-1 standards.
|
E M C standards
|
According with GB9254, EN55022 class A EN61347-2-13:2008 standards
|
Environmental
|
working temperature
|
- 20 ° ~ 60 ° c / 20% ~ 90% RH (no frost)
|
Storage temperature
|
- 40 ° ~ 85 ° c / 10% ~ 95% RH (no frost)
|
height above sea level
|
2000M
|
Structure
|
Size (mm)
|
85(L)*43(W)*30(H)
|
Cooling method
|
Cooling method
|
Natural cooling air convection
|
Weight
|
0.145KG/PCS
|
|