Min. Order: | 1 Set/Sets |
---|---|
Payment Terms: | L/C, T/T |
Supply Ability: | 15 sets/ years |
Place of Origin: | Hunan |
Location: | Changsha, Hunan, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company |
Main Products: | Atomization Equipment, Sintering Furnace, Vacuum Furnace, Melting Furnace, Heat Treatment Furnace |
Means of Transport: | Ocean, Air, Land |
---|---|
Raw Material: | Steel Bar |
Automation: | Automatic |
Certification: | ISO 9001:2000 |
Material / Metal Processed: | Others |
Brand Name: | EasyFashion |
Usage: | metal powder atomizing equipment |
Production Capacity: | 15 sets/ years |
Packing: | Standard export wooden cases and containers |
Delivery Date: | 120 days |
1. Introduciton
The method of powder atomizing equipment is a kind of new technology in the powder metallurgy industry which was developed in recent years. It is with the characteristics of simple craft, easy to master technology, not easy oxidizing material, and high degree of automation.
2.Features
manufacturing most of metal powder and its alloy powder with low production cost
manufacturing spherical or irregular powder
Because of rapid solidification without segregation phenomenon, many special alloy powder can be produced
using right craft can make the powder particle size to achieve a required range
3.Main Technical Parameter
Model of powder atomization equipment | EFSWH-30 | EFSWH- 50 | EFSWH-100 | EFSWH-300 | EFSWH-500 | EFSWH-1000 |
Pressure of High Pressure Water(Mpa) | 100-300 | |||||
Flow of High Pressure Water(L/min) | 50-800 | |||||
Furnace Charging Weight(Kg) | 30 | 50 | 100 | 300 | 500 | 1000 |
Max. Smelting Temperature(°C) | 1750 | |||||
Smelting Heating Power(KW) | 50 | 80 | 130 | 200 | 260 | 400 |
Temperature Measuring Method | Infrared, WRe5.26 | |||||
Tundish Heating Power(KW) | 10-20 | |||||
Supply Power | Three Phase, 380V, 50Hz | |||||
Total Installed Powder(KW) | To be determined | |||||
Flow of Cooling Power (L/min) | 150 | 150 | 150 | 300 | 400 | 700 |
Cooling Water Device | Air cooling tower, water cooling unit, heat exchanger | |||||
Flow of Soft Water(m3/h) | 6-20 | |||||
Control Method | Relay or PLC | |||||
Operating Interface | Button type or touch screen | |||||
Data Record | 12 data curve record, LCD monitor and display | |||||
Overall Dimension(LxWxH)mm | 7500x4000 x6500 | 7500x4200 x6500 | 8200x4200 x6500 | 8200x4500 x6500 | 8500x4500 x6500 | 9200x5000 x6500 |