60245-IEC-66 (YCW) 450/750V Heavy Duty Polychloroprene Or Other Equivalent Synthetic Elastomer Sheathed Cable

Place of Origin: Jiangsu

Company Profile

Location: Wuxi, Jiangsu, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Cable

Product Detail

Model No.: 60245 IEC 66 (YCW)

Product Description

APPLICATION

60245 IEC66(YCW) Heavy Duty Tough Rubber Sheathed Flexible Cable.It is suitable for household appliances,electric tools/instrument and other various moveable electrical equipments of rated voltage up to and including 450/750V.

It is also suitable for weather and oil resistance purpose.

 

BASIC INFORMATION

Code Name 

60245 IEC 66(YCW)

Rated Voltage (Uo/U)

450/750V

Cable Structure

CU/Rubber Insulation/Rubber Sheath

 

 

CONSTRUCTION

Conductor

Number of conductors:1,2,3,4 or 5

The conductors shall comply with the requirement given in IEC 60228 for class 5

The wires may be plain or tinned

Insulation

Rubber compound of Type IE4 according to IEC

Sheath

For single-core cables

– sheath in a single layer, rubber compound of type SE4

For multicore cables

a) Cross-sections not exceeding 10 mm2

– in a single layer, rubber compound of type SE4

b) Cross-sections in excess of 10 mm2

– either in a single layer, rubber compound of type SE4

– or in two layers, with the inner layer made of rubber compound of type SE3 and the outer layer of rubber compound of type SE4




CABLE  STANDARDS

IEC60245,JB/T8735,GB/T5013,BS,DIN,ICEA up on request.

The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the JiangNan Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed.

 

 

CHARACTERISTICS

Conductor temperature

Maximum conductor temperature in normal use: 60℃

Ambient temperature

Permissible Min.temperature is -35℃

The Bending Radius Of Cable(D-Diameter of cable)

D≤25mm: Radius≥4D

D>25mm: Radius≥6D