user login

Aluminium Conductor PVC Insulated Steel Wire Armoured PVC Sheathed Power Cable

Place of Origin: Jiangsu

Company Profile

Location: Wuxi, Jiangsu, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Cable

Product Detail

Application: Others
Type: Others
Insulation Material: PVC
Jacket: Others
Conductor Material: Aluminum
Brand Name: VLV32
Show

Product Description

BASIC INFORMATION

Code Name 

VLV32

Rated Voltage (Uo/U)

0.6/1KV

Cable Structure

Aluminium Conductor/PVC Insulation/PVC Inner Sheath/Steel Wire Armoured/PVC Outer Sheath

 

CONSTRUCTION

Conductor

Number of conductors:1,2,3,4,5,3+1,4+1

The conductors shall comply with the requirement given in IEC

Insulation

PVC(Polyvinyl Chloride) according to IEC

Sheath

PVC(Polyvinyl Chloride) according to IEC

Armoured

Steel Wire

CABLE  STANDARDS

GB/T12706-2008,IEC,BS,ASTM and etc. upon request.

The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the JiangNan Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed.

 

CHARACTERISTICS

Conductor temperature

Maximum conductor temperature in normal use: 70℃

Max.short-circuit temperature

Maximum shall not exceed 160℃(5s Max,Duration)

Installation temperature

Ambient temperature under installation shall not be below 0℃

Minimum bending radius

The bending radius of cable: (D-Diameter of cable) 

-------------------------------------≥15D

Voltage designation

The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of Uo/ U(Um)kV.

Where:

Uo-The rated power-frequency voltage between conductor and screen or   metallic-sheath,for which the cable designed;

U-The rated power-frequency voltage between conductors, for which the cable designed:

Urn-The maximum value of the "hight system voltage " for which the equipment may he operated.

Rated voltaged of cable applied in three phrase system are given in table

 

U

Um

Uo

First class

Second class

1

1.2

0.6

0.6

3

3.6

1.8

3.6

6

7.2

3.6

6

10

12

6

8.7

15

17.5

8.7

12

20

24

12

18

35

42

21

26

 

Post Buying Request