Product Detail

Model No.: GDVA-404
Test sample: CT/PT
Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
Power supply: AC220V±10%,50Hz/60Hz±10%
Power output: 0.1~180V (AC)
Current output: 0.001~5A(RMS)
Size: 485mm*356mm*183mm
Weight: <15Kg
Show

Product Description

  GDVA-404 CT/PT Analizer

 

1.1 Application

Tests for current transformer:

1)Excitation curve and parameters test

2)Turns ratio test

3)Ratio and phase error test

4)Polarity mark check

5)Coil resistance measurement

6)Secondary loop burden measurement

7)Error line curve test for protection CT

8)Transient CT parameters test

9)CT nameplate guess

10)Saturation hysteresis loop curve measurement

Tests for voltage transformer:

1)Turns ratio test and phase angle error test

2)Polarity test

3) Secondary burden test

4) Coil resistance test

 

Applications for CT/PT analyzer:

1)      CT nameplate check

2)      CT parameters check in work burden

3)      CT transient parameters analysis

4)      CT ratio and phase error calibration

5)      PT routine test

1.2 CT/PT analyzer technical index

1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13

2 Power supply: AC220V±10%,50Hz/60Hz±10%

3 Power output: 0.1~180V (AC)

4 Current output: 0.001~5A(RMS)

5 Power output:300VA

6 Maximum knee voltage measurement; 45kv

7 Current measurement:

Range:0~10A (automatically change range in 0.1/0.4/2/10A)           

Error <±0.1%+0.01%FS

8 Voltage measurement:

Range:0~200 V (automatically change range in 1V/10V/70V/200V)

Error < ±0.1%+0.01%FS

9 Turns ratio measurement:

Range :1~35000,

1~2000 error<0.05%

2000~5000 error>0.1%

5000~35000 error<0.2%

10 Phase measurement: error:±2min,resolution:0.01min

11 Coil resistance measurement:

Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)

Error< 0.2%RDG+0.02%FS

Maximum resolution:0.1mΩ

12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree

13 CT Secondary burden:

Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)

Error <0.2%RDG+0.02%FS

Maximum resolution 0.001ohm

14 PT Secondary burden:

Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)

Error <0.2%RDG+0.02%FS

Maximum resolution: 0.1ohm

15 PT ratio measurement:

Range :1~35000,

1~5000 error<0.2%

5000~35000 error<0.5%

16 Saved data groups:>1000groups

17 Work condition: Temperature:-10℃~50℃, moist:≤90%

18 Size: 485mm×356mm×183mm

19 Weight: <15Kg

 

Standard configuration

Name

quantity

Description

Host

1


3M mask cable

2


10M mask cable

1


Grounding cable 6M

1

Diameter size large than4MM

Big test pliers

2

One red and one black

Test gasket

4

Two red and two black

Test pin

4

Two red and two black

Test pliers

4

Two red and two black

Power cable

1


Accessories bag

1


Production disk

1

Include Analysis application and instruction manual

Instruction manual

1


Inspection report

1


Pass certificate

1


 

 