Place of Origin: | Zhejiang |
---|
Location: | Guangzhou, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Meter Testing Equipment, Electric Meter Test Equipment, Portable Meter Test Equipment |
Model No.: | YC98S1 |
---|
It is a portable standard to test three phase meters and single phase meters, designed to work in the field or in the laboratory.
Range |
30-480V |
Error |
±0.05% |
Harmonic |
2nd -- 21st |
Range (direct connection) |
0.1-10A |
Range (clamp CT) |
100A 5A,500A,1000A,2000A (option) |
Error (direct connection) |
±0.05% |
Error (clamp CT) |
±0.2% (5A, 100A ); ±0.5% (other) |
Harmonic |
2nd -- 21st |
Active power (direct connection) |
±0.05% |
Active power (clamp CT) |
±0.2% (5A, 100A); ±0.5% (other) |
Reactive power (direct connection) |
±0.1% |
Reactive power (clamp CT) |
±0.2% (5A, 100A); ±0.5% (other) |
Active energy (direct connection) |
±0.05% |
Active energy (clamp CT) |
±0.2% (5A, 100A); ±0.5% (other) |
Reactive energy (direct connection) |
±0.1% |
Reactive energy (clamp CT) |
±0.2% (5A, 100A); ±0.5% (other) |
Range |
0º – 360º |
Error |
±0.05º |
Range |
45Hz – 65Hz |
High frequency output(CH) |
-- |
Low frequency output(CL) |
3600imp/kWh |
Pulse ratio |
1:1 |
Output level |
5V |
Input channel |
2 |
Input level |
5 -- 10V |
Input frequency |
Max. 100Hz |
Resolution |
7” TFT color (480×234) |
Vector diagram |
Yes |
Waveform |
Yes |
Energy accumulation |
Yes |
CT ratio test |
Yes |
Local parameter input |
Yes |
Wiring emulation |
Yes |
Self-calibration |
Yes |
Recorder check |
Yes |
Data storage |
Yes |
Data storage qty |
5000 |
External extend memory |
Yes |
Screen printing |
Yes |
Communication port |
USB/RS232 |
Communication with PC |
Yes |
Upload data |
Yes |
External mini printer |
Yes |
External keyboard |
Yes |
Voltage Supply way |
External power; test lead power |
Voltage Supply |
55-480V, 50/60Hz |
Ambient temperature |
-25°C -- +45°C |
Relative humidity |
40% -- 95% |
Dimensions (W×H×D) (mm) |
245×168×67 |
Weight (kg) |
1.5kg |