This is a High Accuracy Three Phase Reference Standard Meter, which is suit for Three Phase Energy Meter Test Bench System.

  1. High accuracy up to 0.01%
  2. Test type: 3 phase 4 wire, 3 phase 3 wire
  3. Wide testing range: voltage:5V ~ 480V, current: 1mA ~ 120A
  4. Test mode: active power, reactive power, cross connected reactive power
  5. Waveform display function
  6. Harmonic analysis function
  7. Energy accumulating function
  8. Vector diagram function
  9. Test data can be managed by computer via Rs232 interface

Specifications:

 

SZ03A-K33E

Test Voltage                                                            

Range

5V – 480V

Error

±0.01% (30V – 480V)

±0.03% (5V – 50V)

Display range

5.000000V – 480.0000V

Test Current                                                           

Range

1mA – 120A

Error

±0.01% (0.2A – 120A)

±0.05% (1mA – 0.2A)

Display range

1.000000mA-120.0000A

Power measure error

Active power

±0.01% (0.2A – 120A)
±0.02% (0.01A – 0.2A)
±0.05% (1mA – 0.01A)

Reactive power

±0.05% (0.2A – 120A)
±0.1% (1mA – 0.2A)

Apparent power

±0.05% (0.2A – 120A)
±0.1% (1mA – 0.2A)

Energy measure error

Active energy

±0.01% (0.2A – 120A)
±0.02% (0.01A – 0.2A)
±0.05% (1mA – 0.01A)

Reactive energy

±0.05% (0.2A – 120A)
±0.1% (1mA – 0.2A)

Apparent energy

±0.05% (0.2A – 120A)
±0.1% (1mA – 0.2A)

Phase angle

Range

0º – 360º

Error

±0.002º

Display range

0.000001º --  359.9999º

Frequency

Range

45Hz – 65Hz

Display range

45.0000 – 65.0000

Pulse output

High frequency output(CH)

1×1012 (1mA – 2mA)

1×1011 (2mA – 20mA)

1×1010 (20mA – 0.2A)

1×10(0.2A – 2A)

1×108  (2A – 20A)

1×107 (20A – 120A)

Low frequency output(CL)

2×10-5×CH

Pulse ratio

1:1

Output level

5V

Pulse input

Input level

5V

Input frequency

Max. 1MHz

Other

Voltage Supply

220V ± 10%, 50/60Hz ± 2Hz

Ambient temperature

10°C -- 30°C

Influence of external fields

≤ 0.05 % / mT

Relative humidity

45% -- 75%

Dimensions (W×H×D) (mm)

445×260×480

Weight (kg)

25

 

Applications:

  • Nation-level utility companies
  • Governmental bureaus of metrology
  • Big energy meter manufacturers

Primary Competitive Advantages:

  • High quality product
  • High Accuracy up to 0.01%
  • High stability
  • Friendly interface
  • Convenient operation 
Post Buying Request