user login

600w pure sine wave power inverter with CE approved

50.0~65.0 USD
Min. Order: 100 Piece/Pieces
Trade Term: EXW
Payment Terms: Paypal, L/C, D/P, D/A, T/T, WU
Supply Ability: 10000/month
Place of Origin: Shanghai

Company Profile

Location: Shanghai, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: MK-600PS
Means of Transport: Ocean, Air, Land
Type: DC/AC Inverters
Output Type: Single
Output Power: Others
Brand Name: MKpower or OEM
Size: 250*169*61.5mm
Weight: 2.5kg
Input Voltage: 12V/24V/48V
Output Voltage: 110V/120V/220V/230V/240V
Material of shell: aluminum
Waveform: pure sine wave inverter
color: Black/silver/mazarine
Certificate: CE, LVD, EMC, RoHS, ISO9001-2000
AC outlet: Optional
Advantages: Full load, Strict Test
Accessories: 1 pair of 60cm Clamps
Grid Type: off-grid
Warranty: 1 year
Phase: single phase
Production Capacity: 10000/month
Packing: Carton Packing
Delivery Date: within 3-5 working days after we get 100% payment.
Show

Product Description

600W dc converter 24V 

Application

1. Vehicle and vessel Equipment Series: Military vehicle, police cars, ambulances, ships, trucks, cars, etc.
2. Office Equipment Series: laptop computers, printers, desktop computers, copiers, scanners, program-controlled telephone switches, attendance machine, network equipment, etc.
3. Digital electronic product series: digital cameras, game consoles, Apple iPhones and all kinds of mobile phones, learning machine, MP3 / 4 players, mobile DVD, etc.
4. Household Equipment series: air conditioner, refrigerator, TV, washing machines, electric fans, water heaters, VCR, stereo, DVD, VCD, and microwave ovens.

 

Product Features

 

- High efficiency, fast start.

- Pure sine wave form output.

- Soft start function.

- Strong Adaptability and stability.

- Built-in fuse, safe and reliable.

- DC/AC isolation.

 

Main Function and Protections

 

  • Battery Low Voltage Alarm: When the voltage of battery is lower than normal voltage for a certain range, the inverter will beep to remind the user that the battery needs to be charged. The user should stop the electronic equipment and charge the battery as soon as possible.

  • Battery Low Voltage Protection: When the voltage of battery or power supply is too low, the inverter will shutdown automatically and stop output to avoid the damage of the battery or power supply. When the voltage is back to normal, the inverter returns to work automatically.

  • Battery over-voltage protection: Inverter will shut down automatically when the DC input voltage is more than the normal value for a certain range. Please note that it may damage the machine if the voltage is too high.

  • Over Heat Protection: If the inverter internal temperature or ambient temperature is too high, the inverter will go temperature protection automatically to ensure the safety of electrical equipment.

  • Over Load Protection: When power of the load connected exceeds the rated power (Watt) of inverter, the inverter will shut down automatically and stop output. It would recover and work normally after the removal of overload.

  • Short-circuit Protection: When the load is in short-circuit trouble, the inverter will shut down automatically and stop output. It would recover and work normally after the removal of short-circuits.

  • Earth leakage protection: inverter is made according to the national security leakage protection standards. When leakage of electricity occurs at the grounding terminals, leakage protection circuit will shut down the inverter to avoid the electric shocks.

  •  

     

    Performance Parameter

     

     

    ModelMK-600PS-121MK-600PS-241MK-600PS-481MK-600PS-122MK-600PS-242MK-600PS-482

    Rated power 

    600W600W600W600W600W600W

    Peak power 

    1200W1200W1200W1200W1200W1200W
    DC input voltage12V24V48V12V24V48V
    AC output voltage110VAC220VAC
    No-load current<0.6A<0.3A<0.15A<0.6A<0.3A<0.15A
    AC output frequency60Hz±0.5Hz50Hz±0.5Hz
    AC output waveformPure Sine Wave 
    Waveform distortionTHD<3%(Linear load)
    Efficiency>85%>88%>90%>85%>88%>90%
    DC input voltage range10-15V20-30V40-60V10-15V20-30V40-60V
    Low Voltage Alarm10.5±0.5V21±1V42±2V10.5±0.5V21±1V42±2V
    Low Voltage Shutdown10±0.5V20±1V40±2V10±0.5V20±1V40±2V
    Over Voltage Protection15.5±0.5V31±1V62±2V15.5±0.5V31±1V62±2V
    Low Voltage Recovery12±0.5V24±1V48±2V12±0.5V24±1V48±2V
    Over Voltage Recovery14.8V±0.5V29.5V±1V59V±2V14.8V±0.5V29.5V±1V59V±2V
    Protective FunctionLow/Over voltageLED Red light, automatic recovery
    Over loadLED Red light, automatic recovery
    Over temperature LED Red light, automatic recovery
    Short circuitLED Red light, automatic recovery
    Input reverse connectionFuse Burn-out
    Working Temp.

    32°F to 104°F (0 to 40 C)


    Storage Temp. Humidity

    -22°F to 158°F (-30 to 70 C)

    Dimension250*169*61.5mm

    Weight

    1.8KG

     Qty/Ctn.

    16pcs

     Ctn size

    600*420*320mm

     

       

    Optional Sockets


     

    Accessories

     

    Model No.Input VoltageSpecificationPicture
    MK-600PS12VDCCables: 6mm² 60cm Clamp * 1pair
    24VDCCables: 4mm² 60cm Clamp * 1pair
    48VDCCables: 2.5mm² 60cm Clamp * 1pair

     

     

    More Details

     >>> The inverter shell if made of high-quality aluminum 

    1. The Positive Polarity (+) 2. The Negative Polarity (-) 3. Earth Terminal  4. Cooling Fan 5. Socket
    6. Switch 7. LED Indicator Light  8. No Dismantle Label  9. Basic Parameters

     


     

     

    Wave Form

     

    600W (MKpower Inverter): Pure Sine Wave (Blue) 

     

     

    Outline Dimensions


     

     

    Connection Diagram


     

     

     

    Installation

    1. Put the inverter switch on OFF position and then clip the battery clamps on the positive and negative terminals of the battery. 

    2. Note the positive and negative polarity: the red clip line "O"-shaped terminal should be connected with the red terminal of inverter, the black "O"-shaped terminal should be connected with the black terminals of inverter. Then the red clip connects the battery positive pole, the black clip connects the negative pole of the battery. 

    3. Turn on the inverter switch. If the light is green, the inverter works normally. If red, inverter is faulty. Please check the wires connection. 

    4. Put the plug of the electric equipment into the outlet of the inverter and turn on the switch. If the indicator light is green, the electric appliance works normally. 

    5. Operation procedure: When you use the inverter, please turn on the inverter firstly, and then turn on the electric appliances. When you stop using the inverter, please turn off the electric appliance firstly, and then turn off the inverter.  

    6. When the inverter is working, if the buzzer alarms and the light is red, it indicates that the inverter fails. The user should check the wires connection, DC input voltage and the peak power of loads, etc. After the fault is canceled, the inverter restarts automatically. And then turn off the inverter.  

     

    About us


     

    Certificates


     

    Warning

     

    >>  Do not put the inverter in the raining or humid place, it may cause electric shock.

    >>  Do not insert metals like naked wire into the output socket or inside the inverter through ventilation hole.

         Otherwise it may cause electric shock.

    >>  Do not put the inverter in the place where children can reach, it may cause injure and electric shock.

    >>  When the power inverter is used for a long time, it will be hot, please be careful.

    >>  Keep the inverter from flammable materials, fumes or gases when used.

    >   Proper cooling is necessary while operating.

    >   Please insure the inverter is put at "OFF" position when the vehicle is started, otherwise the large instant peak voltage will possibly damage the inverter or its connected electric appliance.

    >   Reliable connection of the inverter input and DC power output is necessary as the input current is considerable large when inverter is running.

      Notice: the signals with ">>" are the operations which may cause the personal security.

                   the signals with  ">" are the operations which may cause the machine damaging.

     

    After-sales service

     

    Free maintenance service will be offered when there is quality problem under normal use since the date of purchase. If maintenance or adjustment is needed within guarantee period and in the scope of our warranty, 
    please contact with the supplier of the product. The expense shall be borne by the user if any of the following situations happens although within warranty period:
    1. Fault is due to maintenance or adjustment WITHOUT checking or permission of our factory.
    2. Fault or damage is caused by man-made damage, or disassemble by them own, or use of overload, or other natural disasters although within warranty period.
    3. Product is burned because of wrong use of power supply or too high current.
    4. Our company charges to maintenance service over the maintenance period.
    5. The accessories, such as power cord, adapter, fuse, etc are not in the scope of maintenance.


Post Buying Request