Place of Origin: | Zhejiang |
---|
Location: | Shijiazhuang, Hebei, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | High Voltage Cable, Low Voltage Cable, Low Smoke Halogen Free Cable |
Model No.: | BYJ.RYJ.BLYJ.BYJY.BYJV.BLYJY.BYJYB |
---|
Aerial Insulated Cables Within Rated Voltage Up To Including 0.6/1KV
Specification:
Type | Designation |
WDZA-YJY WDZA-YJLY WDZB-YJY WDZB-YJLY WDZC-YJY WDZC-YJLY | XLPE insulated no halogen low smoke A (B or C) class fire retardant power |
WDZA-YJY23 WDZA-YJLY23 WDZB-YJY23 WDZB-YJLY23 WDZC-YJY23 WDZC-YJLY23 | XLPE insulated steel tape armored no halogen low smoke A (B or C) class |
WDZA-YJY33 WDZA-YJLY33 WDZB-YJY33 WDZB-YJLY33 WDZC-YJY33 WDZC-YJLY33 | XLPE insulated fine steel wire armored no halogen low smoke A (B or C) |
WDZA-YJY43 WDZA-YJLY43 WDZB-YJY43 WDZB-YJLY43 WDZC-YJY43 WDZC-YJLY43 | XLPE insulated thick steel wire armored no halogen low smoke A (B or C) |
Type | Cores | Rated Voltage KV | |||||
0.6/1 | 1.8/3 | 3.6/6 6/6 | 6/10 8.7/10 | 8.7/15 | 18/20~26/35 | ||
Nominal Cross-sectional area mm2 | |||||||
WDZA-YJY WDZB-YJY WDZC-YJY WDZA-YJLY WDZB-YJLY WDZC-YJLY | 1 | 2.5~1000 | 10~1000 | 25~1000 | 25~1000 | 35~1000 | 50~1000 |
WDZA-YJY33 WDZB-YJY33 WDZC-YJY33 WDZA-YJLY33 WDZB-YJLY33 WDZC-YJLY33 | 10~10000 | 10~10000 | 25~10000 | 25~10000 | 35~10000 | 50~10000 | |
WDZA-YJY43 WDZB-YJY43 WDZC-YJY43 WDZA-YJLY43 WDZB-YJLY43 WDZC-YJLY43 | 10~10000 | 10~10000 | 25~10000 | 25~10000 | 35~10000 | 50~10000 | |
WDZA-YJY WDZB-YJY WDZC-YJY WDZA-YJLY WDZB-YJLY WDZC-YJLY | 2 3 4 5 3+1 3+2 4+1 | 2.5~400 | 10~300 | 25~300 | 25~300 | 25~300 | 25~300 |
WDZA-YJY23 WDZB-YJY23 WDZC-YJY23 WDZA-YJLY23 WDZB-YJLY23 WDZC-YJLY23 | 4~400 | 10~300 | 25~300 | 25~300 | 25~300 | 25~300 | |
WDZA-YJY33 WDZB-YJY33 WDZC-YJY33 WDZA-YJLY33 WDZB-YJLY33 WDZC-YJLY33 | 4~400 | 10~300 | 25~300 | 25~300 | 25~300 | 25~300 | |
WDZA-YJY43 WDZB-YJY43 WDZC-YJY43 WDZA-YJLY43 WDZB-YJLY43 WDZC-YJLY43 | 4~400 | 10~300 | 25~300 | 25~300 | 25~300 | 25~300 |
Applications:
This product is produced in accordance with RCCE and NF series standards and IEC60502,IEC60332-3,
IEC60754,IEC601034, etc standard. After fired, this product cannot spread combustion and possesses no
halogen, low
smoke, no toxicity, no corrosion and so on characteristics. It is suitable for nuclear power station, underground
facilities, tunnel, high-rise and broadcast television station, etc. fields. It is laid at electric power circuit with
35KV of rated voltage and is used as power transmission/distribution.
Operating characteristics:
The rated voltage(U0/U)0.6/1KV, 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 18/20KV, 21/35 KV, 26/35KV.
Delivery lengths
The single length of cable is not less 100m, shortage length more than 20m may be delivered, but not exceed 10% of the total length, delivered special requirement to be discussed between the supplier and the
buyer, the tolerance of length shall not exceed in ±0.5%.