user login

Accuracy Electronic Single Phase Energy Meter Test Bench Power Source 480V 120A

Place of Origin: Zhejiang

Company Profile

Location: Guangzhou, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Energy Meter Test Bench, Single Phase Energy Meter Test Bench, Three Phase Meter Test Bench

Product Detail

Model No.: KE8801

Product Description

Accuracy Electronic Single Phase Energy Meter Test Bench Power Source 480V 120A

 

 

  1. Name: Portable Standard power source, Portable Power Source
  2. Power: Electronic
  3. Phase: Single phase
  4. Usage: standard power source for Electric meter testing equipment
  5. Voltage Output: 0V – 480V
  6. Current Output: 1mA – 120A
  7. Operating Temperature: -10°C -- +40°C
  8. Two channel pulse input could test 2 single phase meters simultaneously

 

Single Phase Energy Meter Test Bench Power Source 480V 120A

 

KE8801 single phase standard power source adopt advanced digital technique and computer technology, it could be used for electric power company, meter manufacturing company, institutes of metrology as common metering instrument to test the single phase energy meters, power meters, voltmeters, ampere meters, and power frequency phase meters etc.

 

 

Highlight:

  • High accuracy and stability
  • Standard and source are integrated, it could be used as portable test system
  • Wide output range, the voltage output could be 480V, the current output could be 120A
  • 2nd-21st harmonics could be generated and the amplitude and the phase could be freely set
  • Perfect protective alarming function, auto protection of short circuit of voltage, open circuit of current, and overload
  • Full automatic or manual operation
  • Two channel pulse input could test 2 single phase meters simultaneously
  • It could communicate with the computer by the communication interface.

 

Main specifications:

 

Post Buying Request

Voltage output

Output range (P-N)

0V – 480V

Output power of voltage

Max. 25VA

Resolution

1mV

Stability

Better than ± 0.05%  (50 – 400V)

Load regulation rate

Better than ± 0.003% / 150 s

Distortion factor

Better than ± 0.2% (linear resistance load)

Harmonics output

2nd  – 21st free programmable

Current output

Output range

1mA – 120A

Output power of current

Max. 120VA

Resolution

0.002mA

Stability

Better than ± 0.05% (0.1A – 100A)

Load regulation rate

Better than ± 0.003% / 150 s

Distortion factor

Better than ± 0.2% (linear resistance load)