6/10kV AL/ XLPE/ PVC Power Cable

0.5 USD
Min. Order: 1 Kilometer
Payment Terms: L/C, T/T
Supply Ability: 5000km-500000km/month
Place of Origin: Hebei

Company Profile

Location: Shijiazhuang, Hebei, China (Mainland)
Business Type: Manufacturer
Main Products: Cable

Product Detail

Production Capacity: 5000km-500000km/month
Packing: Wooden Drum or Steel Drum, or as request
Delivery Date: Within 15 days once the order is confirmed.

Product Description

 

heat cable/tape

heat tracer cable/heat tracing 

constant wattage heat tracer 

self regualting heating cable


6/10kV AL/XLPE/PVC(or PE) Power Cable


Description

Construction: Compacted stranded circular aluminium conductor, extruded semi-conducting compound as conductor screen, cross-linked polyethylene(XLPE) insulation, semi-conducting compound as insulation screen, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.


U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

U is the rated power frequency voltage between conductors for which the cable is designed;

Um is the maximum value of the "highest system voltage" for which the equipment may be used.

Max. permissible continuous operating temperature of conductor: 90 °C

Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C

The ambient temperature under installation should not be lower than: 0 °C


The bending radius of cable is recommended as following:

For single core cable: not less than 20 times of the diameter of cable

For three core cable: not less than 15 times of the diameter of cable


Application

The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force. 

Single core cable in magnetic duct is not permissible.


Manufacturing Standards GB/T 12706-2008, IEC 60502-2

 Type Description No. of cores Nominal cross section of conductor

YJLV Aluminium conductor/XLPE insulation/PVC outer sheathPower Cable 1 or 3 25~800mm2

YJLY Aluminium conductor/XLPE insulation/PE outer sheath Power Cable 1 or 3 25~800mm2

ZA-YJLV ZB-YJLV ZC-YJLV Aluminium conductor/XLPE insulation flame-retardant Power Cable 1 or 3 25~800mm2

WDZA-YJLY WDZB-YJLY WDZC-YJLY Aluminium conductor/XLPE insulation Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable 1 or 3 25~800mm2