Digital DSP/ARM9 Core Technology Transformer Test System , Portable CT-PT Test Calibrator

Place of Origin: Zhejiang

Company Profile

Location: Guangzhou, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Meter Testing Equipment, Electric Meter Test Equipment, Portable Meter Test Equipment

Product Detail

Model No.: HN-2K01B(Y)

Product Description

Features & function:

  1. Test function: errors, impedance (Z), Admittance(Y), of CTs or PTs.
  2. Automatic and manual selections for test ranges
  3. Automatic switch of resolution level as per the size of measurement data
  4. Automatic setting of test points and accuracy standards in compliance with relevant regulations
  5. Testing speed: 6 times/Sec, with radio errors and angle difference, percentage displayed on one screen, automatically determine qualification of the accuracies.
  6. Automatically make round-off the measurement data, base on the measured precisions class.
  7. RS-232c communication port for printing out the test data displayed on screen
  8. Data storage 200 groups, browsing –by- category function for the measured data.
  9. Communication functions with the data management system by download the measured CT information or uploading the on-site test data.
  10. Protection and alarm functions for wrong polarity during wiring.

Specifications:

 

Technical parameters

Accuracy

1.0 / 2.0

Power supply

AC 220V±20% 50±0.5Hz

Measurement range

Cophase component

0.0001~±20.00

Resolution

0.0001

Quadrature component(point)

0.001~±500

Resolution

0.001

Impedence()

0.0001~10.00

Resolution

0.0001

Admittance(ms)

0.0001~12.00

Resolution

0.0001

Operating range

Current(A)

1%-130%In (In=5A) / 5%-130%In(In=1A)

Voltage(V)

5%-150%Un (Un=100V, , 100/3) 5%-130%Un(Un=150V)

Dimension(LxWxH)

350*260*150

Weight

3kg

 

Description:

This calibrator adopts analog signal conditioning circuit based on the principle of potential difference measurement, the digital circuit with 16-bit DSP and the 32-bit ARM 9 as the core technology.

In calibration process, it can automatically set test points and accuracy standards in compliance with relevant regulations. This calibrator should be used in combination with voltage (or current) standard transformer, voltage (or current) load box, voltage (or current) booster, and voltage (or current) source.