Main Application Fields
Suitable for all kinds of small and medium-sized automation equipment and instruments, such as engraving machine, marking machine, cutting machine, laser typesetting, plotter, numerically controlled machine tools, automatic assembly equipment, etc. The application effect is very good for little noise and high speed equipment.
Drive Function Introduction
Drive Function | Operation Introduction |
Micro-step Subdivide Setting | By SW5-Sw8 four dial code switch to set drive micro-step subdivide value, it has 16 types of micro-step subdivide. When you set micro-step subdivide, you should stop running of the drive. |
Output Current Setting | By SW1-SW3 three dial code switch to set drive output current, it has 8 types. |
Automatic Half Flow Function | By SW4 dial code switch to set up automatic half flow function of drive. Off shows that the static current is set to half of the dynamic current, On shows that the static current is the same as the dynamic current. SW4 should be set off in general use, which can reduce the heating of the motor and drive, improve the reliability. After pulse stops about 0.4 seconds, current automatically reduces to about half (actual value 60%), calorific value reduces to 36%. |
Signal Interface | PUL+ and PUL- are positive pole and negative pole of the control pulse signal; DIR+ and DIR- are positive pole and negative pole of the direction signal. ENA+ and ENA- are positive pole and negative pole of the enable signal. |
Motor Interface | U,V,W correspond to motor winding wires U,V,W; By exchanging two of three winding wires, can change the direction of motor. |
Power Interface | 220V VC power supply, working voltage 80-220VAC, Power consumption more than 500W. |
Indicator Light | Drives have two indicator light. Green light is power indicator light, when drive has electric, it is on; Red light is failure indicator light, when over voltage and over current happen, it is on. After the failure is solved, red light will be out. If failure happened, only drive is energized again, the failure can be solved. |
Install Instruction | Drive shape size: 197×105×86mm, Installment pitch of holes is 183mm. Install has horizontal type and vertical type, we suggest to use vertical type. Drive should keep close to metal cabinet for dissipating heat. |
Parameter Setting
3M2060 drive uses 8 dial code switch to set micro-step subdivide, dynamic current, half/full current. Detailed description is as follows:
Working Current Setting 0=off 1=on
Output Reference Current | SW1 | SW2 | SW3 |
1.3A | 0 | 0 | 0 |
1.8A | 1 | 0 | 0 |
2.5A | 0 | 1 | 0 |
3.1A | 1 | 1 | 0 |
3.7A | 0 | 0 | 1 |
4.3A | 1 | 0 | 1 |
5.0A | 0 | 1 | 1 |
5.6A | 1 | 1 | 1 |
Micro-step Subdivide Setting 0=off 1=on
steps/rev | SW5 | SW6 | SW7 | SW8 |
200 | 0 | 0 | 0 | 0 |
400 | 1 | 0 | 0 | 0 |
500 | 0 | 1 | 0 | 0 |
800 | 1 | 1 | 0 | 0 |
1000 | 0 | 0 | 1 | 0 |
1250 | 1 | 0 | 1 | 0 |
1600 | 0 | 1 | 1 | 0 |
2000 | 1 | 1 | 1 | 0 |
2500 | 0 | 0 | 0 | 1 |
3200 | 1 | 0 | 0 | 1 |
4000 | 0 | 1 | 0 | 1 |
5000 | 1 | 1 | 0 | 1 |
6400 | 0 | 0 | 1 | 1 |
8000 | 1 | 0 | 1 | 1 |
10000 | 0 | 1 | 1 | 1 |
12800 | 1 | 1 | 1 | 1 |