user login

3M2060 series Three-phase stepper motor drive

Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer

Product Description

Main Application Fields

Suitable for all kinds of small and medium-sized automation equipment and instruments, such as engraving machine, marking machine, cutting machine, laser typesetting, plotter, numerically controlled machine tools, automatic assembly equipment, etc. The application effect is very good for little noise and high speed equipment.

 

 

Drive Function Introduction

Drive   Function

Operation Introduction

Micro-step   Subdivide Setting

By   SW5-Sw8 four dial code switch to set drive micro-step subdivide value, it has   16 types of micro-step subdivide. When you set micro-step subdivide, you   should stop running of the drive.

Output Current Setting

By SW1-SW3 three dial code switch to set   drive output current, it has 8 types.

Automatic Half   Flow Function

By SW4 dial code switch to set up   automatic half flow function of drive. Off shows that the static current is   set to half of the dynamic current, On shows that the static current is the   same as the dynamic current. SW4 should be set off in general use, which   can  reduce the heating of the motor   and drive, improve the reliability. After pulse stops about 0.4 seconds,   current automatically reduces to about half (actual value 60%), calorific   value reduces to 36%.

Signal Interface

PUL+ and PUL- are   positive pole and negative pole of the control pulse signal; DIR+ and DIR-   are positive pole and negative pole of the direction signal. ENA+ and ENA-   are positive pole and negative pole of the enable signal.

Motor Interface

U,V,W   correspond to motor winding wires U,V,W;  By exchanging two of three winding wires,   can change the direction of motor.

Power Interface

220V   VC power supply, working voltage 80-220VAC, Power consumption more than 500W.

Indicator Light

Drives   have two indicator light. Green light is power indicator light, when drive   has electric, it is on; Red light is failure indicator light, when over   voltage and over current happen, it is on. After the failure is solved, red   light will be out. If failure happened, only drive is energized again, the   failure can be solved.

Install Instruction

Drive   shape size: 197×105×86mm, Installment pitch of holes is 183mm. Install has horizontal   type and vertical type, we suggest to use vertical type. Drive should keep   close to metal cabinet for dissipating heat.

 

Parameter Setting 
3M2060 drive uses 8 dial code switch to set micro-step subdivide, dynamic current, half/full current. Detailed description is as follows:


 

Working Current Setting   0=off      1=on

Output Reference Current

SW1

SW2

SW3

1.3A

0

0

0

1.8A

1

0

0

2.5A

0

1

0

3.1A

1

1

0

3.7A

0

0

1

4.3A

1

0

1

5.0A

0

1

1

5.6A

1

1

1

 

Micro-step Subdivide Setting  0=off      1=on

steps/rev

SW5

SW6

SW7

SW8

200

0

0

0

0

400

1

0

0

0

500

0

1

0

0

800

1

1

0

0

1000

0

0

1

0

1250

1

0

1

0

1600

0

1

1

0

2000

1

1

1

0

2500

0

0

0

1

3200

1

0

0

1

4000

0

1

0

1

5000

1

1

0

1

6400

0

0

1

1

8000

1

0

1

1

10000

0

1

1

1

12800

1

1

1

1

 


Post Buying Request