user login

Photovoltaic PV Hybrid Solar UPS Charger with Zero Transfer Time

Place of Origin: Zhejiang

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Uninterrupted Power Supply, Offline UPS, High Frequency Online UPS

Product Detail

Model No.: Bright Star Series 1-3Kva

Product Description

Photovoltaic PV Hybrid Solar UPS Charger with Zero Transfer Time                               

Model: Solar PV Online UPS Bright Star Series 1K-3Kva ( 1ph in / 1ph out )                          

 

Solar UPS Overview

1: Solar UPS with Both AC Input and PV Input

2: Solar UPS with max PV Input 150Vdc

3: Solar UPS Inbuilt Mppt Charger Controller 30Amp - 50Amp

4: Solar UPS with Online Double Conversion Tech

 

Working Principle    

                    
1: PV Charges DC CAP with its maximum power and DC-DC booster work with +/- 390Vdc, if load power        

     is bigger than PV power, the DC CAP voltage will drop and DC-DC booster output voltage will decrease        
     too, AC-DC booster works with +/-360Vdc, thus it will share the load power automatically between PV          
     AC. So the DC CAP voltage will reach to a stable value. Battery SCR Q1 stops if line voltage is normal          
2: If PV power is bigger than load power, MPPT charger autoatically charges the battery. MPPT charger       
     works in fload voltage mode, MPPT mode if battery voltage and DC CAP Voltage are high.                        
3: If AC loose, stop AC-DC booster, switch on batter SCR Q1, make battery and PV works together to             
     power for the load.                        
4:  If both PV and AC not there, battery works to power the load as the last option.                        
                        

Absolute advantages            

            
1: No affexted by nation power regulartion policy                        
2: Ouput voltage is stable. Zero transfer time between line mode and battery mode.                        
3: Battery works in normal situation, not frequently discharged and the life time is extended max long.                        
4: UPS works even in very low AC voltage when PV is also in picture together sharing the load.                        

                        
Technical Specification

 

Model

B1K

B2K

B3K

Rating

1KVA/800W

2KVA/1600W

3KVA/2400W

Input

Rated Voltage

220V/230V/240Vac

Phase

Single Phase with ground

Frequency

50Hz(60Hz)

Power Factor

0.99

Generator

Support generator input

Rated Current

5A

10A

15A

Input Thdi

≤10%

Protection

10A AC fuse

20A AC fuse