user login

Auto Defrost Function Three-zone Temperature Test Chamber , Thermal Shock Chamber

Place of Origin: Zhejiang

Company Profile

Location: Dongguan, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Digital Hardness Tester, Vickers Hardness Tester, Micro Hardness Tester

Product Detail

Model No.: QT3-56A

Product Description

Thermal shock test chamber is used to test products in alternating extremes of high and low temperatures in order to observe changes in product characteristics and failure occurrence.


QT3 series air-to-air thermal shock chambers circulate cold, hot, or ambient air as needed. The conditioned air is pre-cooled or pre-heated beyond the set point, allowing quicker recovery of the desired condition after transfer. 

 

 

QT3 Series Chambers Conform Following Testing Standards:


MIL-STD-883E Method 1011.9 Thermal Shock


MIL-STD-202G Method 107G Thermal Shock


JIS C 0025 Basic Environmental Testing Procedures Part 2: Tests, Test N: Change of Temperature 


IEC 61300-2-47:2004 Fiber Optic Interconnection devices and passive components-Basic Test and Measurement Procedures – Part 247: Tests – Thermal Shocks


JEDEC STANDARD JESD22-A104C Temperature Cycling 


GB/T 2423.22-2012 Environmental testing - Part 2: Tests methods - Test N: Change of temperature


Others related standards and test methods: SJ/T10186-91Y73, GJB150.5, GJB360.7, GB/2423.22

 

 

Chamber Dimensions: 

Model

Interior Dimension

(W ×H × D)

Interior Volume

Exterior Dimension

(W ×H × D)

Specimen Loading Weight

QT3-56A/B/C

400 ×350× 400mm

15.7”×13.8”×15.7”

56L

1450× 1950 ×1600mm

57.1” ×76.8” ×63.0”

2.5Kg

QT3-80A/B/C

500 ×400× 400mm

19.7”×15.7”×15.7”

80L

1550× 2050 ×1600mm

61.0” ×80.7” ×63.0”

5.0Kg

QT3-150A/B/C

600 ×500× 500mm

23.6”×19.7”×19.7”

150L

1650× 2150 ×1800mm

64.9” ×84.7” ×70.9”

7.5Kg

QT3-225A/B/C

750 ×600× 500mm

29.5”×23.6”×19.7”

225L

1850× 2250 ×1800mm

72.8” ×88.6” ×70.9”

7.5Kg

 

 

Specifications:

 

Structure

Pre-cooling Zone, Pre-heating Zone, Testing Zone 

(Selectable 2-Zone or 3-Zone Test for stationary object test)

Damper Device

Forced Air Damper

Interior Material

SUS#304 Stainless Steel

Exterior Material

Stainless steel with environmentally baking paint

Testing Shelves

Stainless Steel Plate

Refrigeration

Cascade Refrigeration System

Cooling Method

Water/Air Cooling

Ambient Temperature

530

Pre-heating Temperature

80200

Pre-cooling Temperature

40 (60/75)10

High Temp. Shocking

60150

Low Temp. Shocking

A=350

B=5510

C=6510

Temp. Uniformity

Less than ±2

Transition time

<10 seconds

High Temp. Recovery Time

RT150/5min

Low Temp. Recovery Time

RT75/5min

Pre-heating Time

40min (30min for 56L)

Pre-cooling Time

80min (60min for 56L)

Controller

Powerful interactive LCD touch screen controller

Setting Range

Temperature: 200300

Time: 0H1min9999H59min

Cycle: 19999cycle

Resolution

Temperature: 0.1

Time: 1min

Control Method

PID+SSR

Power supply

AC380V/50Hz/3P

Accessories

Cable Port, LCD touch screen controller, Power cable

Security System

Overheat Protector, Compressor overload protector, 

Controller protector, Motor overload protector

Note:
1. Ambient temperature of +23 and a cooling water temperature of +25
2. During pre-heating, prevention for temperature heat-up may be worked
3. Performance shown above conforms to IEC61300-2-47
4. Temperature heat-up/pull-down time is applicable only during independent chamber operation

 


Features:
Automatically setting of pro-cooled and pre-heated air.
Testing samples don’t move, cable port is available for power on testing.
Powerful interactive touch screen controller, easy operation and setting 
High accurate temperature recovery with PID auto tuning
Auto defrost function 

Post Buying Request