PLD5000C High Performance x-ray fluoroscopy unit  

 Brand of Hot selling x ray radiation is perlong medical,

x-ray equipment /fixed x ray is one of medical x ray series , stationary x ray machine.

 

 

 

 

 

Usages of 500mA x ray machine | medical radiography x ray machine


        This surgical  x ray machine  must only be operated by the professional who has necessary radiation knowledge and get professional training.  
This machine is used to photograph patient's esophagus, chest, gastrointestinal, abdomen, limbs etc for common radiography, Beam Limiting Device radiograph and high KV radiography.

 

  

 

 

Technical parameters of 500mA x ray machine | medical radiography x ray machine

 

Power condition


Three phase four line

AC  380V ± 38V, 50Hz ± 1Hz

Power inner resistance

no more than 0.17∏

Power content

no less then 50kVA

Using environment


Environment temperature

10℃-40 ℃

Relative humidity

30%-85%

Atmosphere air pressure range

70KPa-106KPa

X-ray high voltage generator


Maximum Power

40kW

Dual-focus

1.0/2.0

kV Range

44~125kV

Inverter Frequency

50HZ

mA Range

Exposal:32~500 mA    

Fluoroscope:0.5~5 mA

mAs Range

Large focus:4~400mAs;

Small focus :0.64~320mAs

Heating Power

300W

Monitor

14" high definition medical monitor

 

 

 

 

Features of 500mA x ray machine | medical radiography x ray machine


1.The console applies LCD display photograph term, the device have the mA, kV of photograph table projection chosen are controlled by procedure interlock, be separate ,not disturb.

2.Use the microprocessor limited-time control, to achieve the precise control of the expose time.

3.Select the exposure tube current at the same time to determine the focus.

4.This machine adopts mA, KV, s three parameters free matching work method.

5.The limit time of fluoroscope of this machine is controlled by program.

6.Expose mode of this machine use two-step hand-swicth control mod, hand swicth control circuit adopt a safe voltage control.