Application

 

Vehicle Loop detectors are used wherever vehicles have to be detected such as monitoring and safe guarding access ways or for counting vehicles. The output signal can be used for controlling door and gate drive mechanisms, operating barriers, controlling traffic light systems in car parks or activating card dispensers in car parking lots.Model TLD-110 connects one inductive loop.

 

Operation and Indication


When the power is applied, the red Power LED will glow and the detector is tuning, the green Check LED blink about 3 seconds. The green LED will also glow whenever a vehicle is detected passing over the inductive loop. If a loop fault exists the green LED will come on and flash indicating a fault.

Frequency


To eliminate interference of two neighbouring wire loops or loop detectors,
the frequency can be altered by DIP4 on the main board in the box.

 

 Sensitivity


The response sensitivity can be set using the threestage switch on the front. The setting “L”
corresponds to the lowest sensitivity. “M” is the medium sensitivity and “H” is the highest
sensitivity.After the sensitivity has been set, a reset and a calibration automatically takes place.


Attention If the detector isn’t working normally, you must check the loop and wiring at first,
and then alter the frequency or the sensitivity.


 Output Relay


The output of relay 2 can be programmed by means of DIP3 Switch.
If DIP3 is “OFF” site, the output is presence output. When a vehicle is detected passing over
the inductive loop, the relay 2 is energized( Pin3 and Pin4 is shorted) until the vehicle is detected
leaving the loop. If DIP3 is “ON” site, the output of redlay 2 is same as relay 1.
The output of relay 1 can be programmed by means of DIP1 and DIP2 Switch.



Reset


The detector automatically reset and tune to the inductive loop when the power is applied,
whether on initial installation or after any break in power supply. Should it be necessary to retune the
detector, as may be required after changing any of the switches or after moving the detector from one
installation to another.

 

Technical parameters:

1. Model TLD-410 with double loops

2. Operating temp.: -20C~ +65C

3. Storage temp.: -40C~ +85C

4. Frequency range: 20 kHZ to 170 kHz,2 grades adjustable

5. Reaction Time:100ms

6. Installation: DIN rail

7. Dimensions: 75×37×110 mm (L×W×H)

8. Net Weight: 400g

9. Operating voltages:AC220V±10%

10. Power consumption: 5W

11. Relay output: DC24V /3A

12.Reaction time: 20 ms

13.Connection: 11-pin socket

14.Sensitivity:Adjustable in 3 increments

15.Loop inductance: Ideal 100µH300µH(include connecting wiring); Max 50µH1000µH(include

      connecting wiring)

16.Loop connection wiring:Maximum length 20 meters,twisted at least 20 times per meter

17.Size of Housing:78*40*108mm

 

 

 