NT6102 dosimeter radiometer chinacoal08

Min. Order: 1 Set/Sets
Payment Terms: T/T, WU
Supply Ability: 1000sets/month
Place of Origin: Shandong

Company Profile

Location: Jining, Shandong, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Electric Motor, Instrument And Meter, Steel Products, Chemical Equipment

Product Detail

Production Capacity: 1000sets/month
Packing: carton box, plastic bags, wooden cases or as your requirement
Delivery Date: 5-10 days after your payment

Product Description

Chinacoal08

Purpose of use

l Measurement of personal gamma and X-ray radiation equivalent dose rate(EDR)

l Measurement of personal gamma and X-ray radiation equivalent dose(ED)

l Alarm of exceeded programmed threshold levels

Application

l Nuclear facilities around environmental radiation detection

l The soil surface radiation pollution detection

l Agricultural radiation pollution detection

l Ore, building materials radioactive detection

l Personal dose monitoring alarm

l Industrial X, gamma NDT radiation detection

l Radiation medical treatment place radiation detection

l Cobalt source, electronic accelerator irradiation place radiation detection

l Radioactive radiation laboratory detection

Specification

1. Types of measured Ray: X, γ and hard-β rays 

2. Measurement range:

Radiation equivalent dose rate(EDR):  0.01 µSv/h - 10000µSv/h

Radiation equivalent dose(ED): 

0.00 µSv - 9999Sv

3. Energy ranges of measurement: 

40KeV - 3.0MeV

4. Relative errors of energy dependence(137Cs): ≤±25% 

5. Basic relative errors::

 ≤±15%

6. Adjustable range of alarm threshold level relative to radiation dose rate: adjustable within the range 

7. Adjust able range of alarm threshold level relative to radiation dose: adjustable within the full range 

8. Response time of alarm: ≤5seconds

9. Display unit: 

EDR :(µSv/h,mSv/h,Sv/h )

Count Rate:cpm

    ED:(µSv,mSV,Sv)    

10. Power: one AAA battery 

11. Dimension: 105*55*26 (mm)

12. Weight: 80g (excluding battery)

Specification

 

Types of measured Ray

X, γ and hard-β rays 

Measurement range

Radiation equivalent dose rate(EDR)

0.01 µSv/h - 10000µSv/h

Radiation equivalent dose(ED)

0.00 µSv - 9999Sv

Energy ranges of measurement

40KeV - 3.0MeV

Relative errors of energy dependence(137Cs)

less than or equal±25% 

Basic relative errors

less than or equal ±15%

Adjustable range of alarm threshold level relative to radiation dose rate

adjustable within the range 

Adjust able range of alarm threshold level relative to radiation dose

adjustable within the full range 

Response time of alarm

Less tan or equal 5seconds

Display unit

EDR

(µSv/h,mSv/h,Sv/h )

Count Rate

cpm

ED

(µSv,mSV,Sv)  

Power

one AAA battery 

Dimension

105*55*26 (mm)

Weight

80g (excluding battery)

 


Post Buying Request