user login

concrete floor repair products used for high way and Municipal road and other cement defect road

1500.0~1800.0 USD
Min. Order: 5 Ton
Trade Term: FOB
Payment Terms: L/C, D/P, D/A, T/T, WU
Supply Ability: 1000
Place of Origin: Henan

Company Profile

Location: Zhengzhou, Henan, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Concrete Repaid Repair Materials, Concrete Driveway Crack Repair Materials, Best Concrete Waterproof Repair Mortar, Best Material For Filling Cracks In Concrete Driveway, Bridge Deck Expansion Joint Repair Solution

Product Detail

Model No.: BC
Means of Transport: Ocean, Air, Land
Brand Name: HN
color: gray
compressive strength: 1days>40Mpa
Drawing strength: 28days>2.5Mpa
Expansion: 0.06%(28days)
Storage period: six months
package: 25kg
open transportation time: 2hours
Suitable temperature: >0
Production Capacity: 1000
Packing: 25kg
Delivery Date: 5-7days
Show

Product Description

concrete floor repair products

1.Product introduction of concrete floor repair products

BC-type concrete pavement patching material is ideal material for a professional to solve concrete pavement surface disease. Located efficiently cure the road from the skin, sand, freezing and thawing, explicit, crazing and other diseases. After adding water, stir the material directly applied in disease site.2h after patching to open transportation.

2.Scope of application of concrete floor repair products

Airport runways, highway, road, municipal, tunnels, bridges, general concrete floor

3.Product advantage of concrete floor repair products

1)High bond strength, 

2)high compressive strength, 

3)antifreeze, 

4)salt corrosion resistance, 

5)wearable. You can thin patch; not broken and does not fall off at high speed and high pressure driving condition.

4.Technical parameters

 Test items

Unit

Technical Requirements

 Test   results

Individual conclusions

Setting time

Initial setting

Min

≥15

20

Meet the requirements

Final setting

≤60

28

Compressive strength

1h

Mpa

≥20

28

Meet the requirements

1d

≥30

63

28d

≥50

95

Drawing strength

28d

Mpa

≥2.0

2.8

Meet the requirements

Expansion

28d

/

  0.00%-0.1%

    0.02%

Meet the requirements

5:certification: