Introduction
Model HYVA-405
Tests for Current Transformer: 1 Excitation curve and parameters test Tests for Voltage Transformer: 1 Turns ratio test |
Application
CT PT Tester application 1 CT nameplate check 2 CT parameters check in work burden 3 CT transient parameters analysis 4 CT ratio and phase error calibration 5 PT routine test |
Technical index
1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 2 Power supply: AC220V±10%, 50/60Hz±10% 3 Voltage output: 0.1~180V (AC) 4 Current output: 0.001~5A(RMS) 5 Power output: 500VA 6 Maximum knee voltage measurement: 45KV 7 Current measurement: Range: 0~10A (automatically change range in 0.1/0.4/2/10A) Error: <±0.1%+0.01%FS 8 Voltage measurement: Range: 0~200V (automatically change range in 1V/10V/70V/200V) Error: < ±0.1%+0.01%FS 9 Turns ratio measurement: Range:1~35000 1~2000 error<0.05% 2000~5000 error<0.1% 5000~35000 error<0.2% 10 Phase measurement: error: ±2min; resolution: 0.01min 11 Winding resistance measurement: Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error: < 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ 12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree 13 CT Secondary burden: Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error: <0.2%RDG+0.02%FS Maximum resolution: 0.001ohm 14 PT Secondary burden: Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error :<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15 PT ratio measurement: Range: 1~35000 1~10000 error<0.1% 10000~35000 error<0.2% 16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1% 17 PT phase angle measurement: maximum error < 3min 18 Make evaluation for test results according to selected standards 19 Make word report for test result 20 Make word reports one time for multi-group test records on the PC 21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test 22 Compare excitation curves with saved excitation curves in the same window 23 Memory capacity: >1000 groups test results 24 Working condition: temperature: -10℃~50℃; moist: ≤90% 25 Size: 485mm×356mm×183mm 26 Weight: <15kg |