Place of Origin: | Zhejiang |
---|
Location: | Hangzhou, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Electronic Energy Meter, Single Phase Energy Meter, Three Phase Energy Meter |
Model No.: | XLE12KP |
---|
Keypad Type Multifunction Energy Meter for Residential & Commercial applications
Quick Detail:
The XLE12KP is the latest evolution in electricity prepayment metering from XILI.
The XLE12KP utilizes the well-proven STS standard keypad technology for one-way credit and debt management. With a modern design and 10 year certification life, the small and compact XLE12KP offers significant additional operational benefits over existing meter types
Description:
Meter status and diagnostic indicators
The meter includes a LED status indicator. This allows a technician to view the operational status of the meter without the need for specialized interrogation tools or having to gain access to the consumer’s premises.
LCD display on the meter
The XLE12KP meter model is fitted with a large clear display to enable field staff to read the meter parameters. This meter can be configured at the time of manufacture to show total kilowatt-hours consumed to date as a running total, while consumers are able to see the remaining kilowatt-hours.
Easy and Secure Data Transfer
Data transfer from a Point of Sale is made via 20 digits token highly encrypted according to STS standard (IEC62055-41/51)
Applications:
Single-phase two-wire, direct connected energy meter for residential applications.
Specifications:
Type |
Single-phase Two-wire, direct connected energy meter |
Reference voltage (Un) |
230 Volts AC (other voltages available on request) |
Reference Frequency (Fr) |
50 Hz or 60 Hz |
Extended Operating voltage range |
70%-115% Un |
Basic Current (Ib) |
5, 10 A |
Maximum Current (Imax) |
Selectable 40, 60, 80A |
Short-circuit ≤ 10 ms |
30 Imax |
Measuring Accuracy |
Active energy to IEC 62053-21 class 1 (Higher rating available on request) |
Starting current |
0.4% Ib |
Burden |
≤10VA,1.8W |
Protective Class |
Class II (double insulated) IEC 62052-11 |
Operation temperature rage |
-20+55 |
Storage temperature rage |
-25+60 |
Life span |
10 years |
Reference standard |
IEC 62052-11; IEC 62053-21 |