Min. Order: | 100 Piece/Pieces |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, T/T, WU |
Supply Ability: | 100000PCS/PER MONTH |
Place of Origin: | Zhejiang |
Location: | Wenzhou, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company, Agent |
Main Products: | Distribution Box, Low Voltage Switchgear Cabinet |
Model No.: | KXX2-D115/800 |
---|---|
Means of Transport: | Ocean, Air, Land |
Type: | Others |
Poles Number: | 3 |
Brand Name: | CHKX |
Rated working current Ie(AC-3 (380V)): | 9-95 |
Rated working current Ie(AC-3 (6600V)): | 6.6-49 |
Rated working voltage(Ue)V: | 690,380 |
Rated isolating voltage(Ui)V: | 690 |
Auxiliary contact conventional free air heating current Ith (A): | 10 |
Action mechanic: | directing acting type |
Installation altitude: | can't exceed 2000m |
Pullution degree: | III |
Installation degree: | III |
Power supply frequency: | 50,60 |
Production Capacity: | 100000PCS/PER MONTH |
Packing: | Neutral or customized |
Delivery Date: | 30 days or customized |
KXX2-D AC contactor series
◎Application:
KXX2-D series AC contactor mainly used to circuit with AC 50Hz(or 60Hz), rated voltage till 690-1000V, in the usage AC-3 rated working voltage is 380V, rated working current till 115A-800A, for long distance connect and break circuit, also can combine with suitable thermal relay to consist of electromagnet starter, for overload circuit protection.
◎Model No. and meaning:
◎Structure feature:
◆Contactor mainly consist of arc extinguishing system, contact system, base, magnetic system(include iron core, coil) etc;
◆contactor contact system is directing acting type, double breakpoint, bottom base adopt aluminum alloy section, coil use plastic enclosed structure, coil combined with magnet yoke, can be removed and load from contactor directly, easy to operate and maintain;
◆Contactor can install additional 2 auxiliary contact group (max 8 pairs contact)
◆Contactor with short arc, it's only around 1/6 of other same volume contactor arc. Can save occupy space while it used in complete device, it's excellent component for electric control device
◆Building block installation type to install additional auxiliary contact group, air time delay head and other accessory;
◆Contactor can install additional interlock vertically or horizontally.
◎Working and installation criteria
◆Surrounding temperature range: -5℃~+40℃
◆The altitude of installation place should lower than 2000m.
◆Atmospheric relative humidity should lower than 50% when the temperature is +40℃, higher relative humidity is acceptable when the temperature lower than +40℃, max relative humidity can reach 90% when the temperature at +20℃, should have special policy in condensation condition which may caused by temperature changing.
◆Installation place shouldn't have obvious impact or shake, no dangerous explosion neurogen, no etchant gas, and can't hit by dust, rain or snow
◆Installation type: III or II
Technical parameter | KXX2-D115 | KXX2-D150 | KXX2-D170 | KXX2-D205 | KXX2-D245 | KXX2-D300 | KXX2-D410 | KXX2-D475 | KXX2-D620 | KXX2-D800 | KXX2-D780 | |||||||
Rated working current Ie(A) | AC-3 | 380V | 115 | 150 | 185 | 225 | 245 | 330 | 400 | 500 | 630 | 800 | 780 | |||||
660V | 86 | 107 | 118 | 135 | 170 | 225 | 305 | 355 | 460 | 485 | 485 | |||||||
AC-4 | 380V | 52 | 60 | 79 | 85 | 105 | 117 | 138 | 147 | 188 | 242 | 242 | ||||||
660V | 49 | 57 | 69 | 82 | 98 | 107 | 135 | 145 | 170 | 215 | 215 | |||||||
Controllable three phase squirrel cage type motor max power pe(kw) | AC-3 | 380V | 55 | 75 | 90 | 110 | 132 | 160 | 200 | 250 | 335 | 450 | 400 | |||||
660V | 80 | 100 | 110 | 129 | 160 | 220 | 280 | 335 | 450 | 475 | 475 | |||||||
AC-4 | 380V | 25 | 30 | 40 | 45 | 55 | 63 | 75 | 80 | 100 | 129 | 129 | ||||||
660V | 45 | 51 | 63 | 75 | 90 | 100 | 129 | 140 | 160 | 200 | 200 | |||||||
Conventional free air thermal current (Ith) A | 200 | 200 | 200 | 315 | 350 | 400 | 500 | 630 | 800 | 1000 | 1200 | |||||||
Rated working voltage (Ue) V | 380,660,1000 | |||||||||||||||||
Rated isolating voltage (Ui) V | 1000 | |||||||||||||||||
Criteria | IEC60947-4-1, GBI4048.4 | |||||||||||||||||
AC-3 | Electric life(times) | 60*10000 | 50*10000 | 30*10000 | 20*10000 | 15*10000 | ||||||||||||
Operation frequency h-1 | 600 | 300 | 150 | |||||||||||||||
AC-4 | Electric life(times) | 15*10000 | 8*10000 | 5*10000 | 3*10000 | |||||||||||||
Operation frequency h-1 | 150 | |||||||||||||||||
Mechanical life(times) | 3*106 | 1*106 | 0.6*106 | |||||||||||||||
Auxiliary contact | Conventional free air thermal current (Ith) A | 10 | ||||||||||||||||
Electric life(times) | AC-15 | 60*10000 | 50*10000 | 30*10000 | 20*10000 | 15*10000 | ||||||||||||
AC-13 | ||||||||||||||||||
Coil parameter | Rated control power supply (Us)V | 24,48,110,220,380 | 48,110,220,380 | |||||||||||||||
Pull-in voltage | 0.85-1.10Us | |||||||||||||||||
Release voltage | 0.20-0.75Us(DC control 0.1-70%Us) | |||||||||||||||||
Coil power VA | Pull-in | 550 | 800 | 1200 | 1200 | 1250 | 1650 | 2600 | ||||||||||
Hold | 45 | 55 | 13 | 20 | 24 | 22 | 44 | |||||||||||
Pull-in time ms | 23-35 | 20-35 | 30-65 | 40-75 | 40-80 | 50-100 | ||||||||||||
Release time ms | 5-15 | 7-15 | 100-170 | 100-170 | 100-200 | 130-230 | ||||||||||||
Coil power W | 12-16 | 18-24 | 12 | 14 | 18 | 20 | 40 |
◎Overall size, installation size and wire connecting
KXX2-D115,150,170 contactor
KXX2-D115N,150N,170N mechanical interlock contactor
◆KXX2-D115-D300 overall size and installation size (see drawing 1 and table 2)
Drawing 1:
Table 2
Product Model No. | amax | bmax | b1max | cmax | G | L | P | Q | Q1 | S | X | Z | Y | fmin | kmin |
KXX2-D115 | 165 | 170 | 137 | 171 | 80±0.8 | 107 | 37 | 29.5 | 60 | 15 | 57 | 26.5 | M6*15 | 133 | 40 |
KXX2-D150 | 165 | 170 | 137 | 171 | 80±0.8 | 107 | 40 | 26 | 57.5 | 20 | 57 | 26.5 | M6*20 | 133 | 40 |
KXX2-D170 | 171 | 197 | 137 | 181 | 80±0.8 | 113.5 | 40 | 30 | 60 | 20 | 59.5 | 29 | M6*20 | 133 | 40 |
KXX2-D205 | 171 | 197 | 137 | 181 | 80±0.8 | 113.5 | 48 | 22 | 52 | 25 | 59.5 | 29 | M6*30 | 133 | 40 |
KXX2-D245 | 204 | 203 | 145 | 231 | 96±1.1 | 141 | 48 | 39 | 66.5 | 25 | 61 | 44.5 | M10*30 | 146 | 50 |
KXX2-D300 | 213 | 206 | 145 | 219 | 96±1.1 | 145 | 48 | 43 | 74 | 25 | 67 | 50.5 | M10*30 | 146 | 60 |
Note: fmin main replacement coil necessary space, kmin is min electric distance, as well as below tables.
◆KXX2-D410-D475 overall size and installation size(see drawing 2, table 3 and table 4)
Drawing 2:
Table 3
Product Model No. | amax | bmax | cmax | fmax | kmax | S | J | L | P | Q | Q1 |
KXX2-D410 | 231 | 206 | 206 | 146 | 70 | 25 | 19.5 | 145 | 48 | 43 | 74 |
KXX2-D475 | 233 | 238 | 238 | 150 | 70 | 30 | 39.5 | 146 | 55 | 46 | 77 |
Table 4
Product Model No. | Size code | Nominal value | max | min |
KXX2-D410 | G | 80 | 102 | 66 |
G1 | 180 | 192 | 156 | |
KXX2-D475 | G | 80 | 120 | 66 |
G1 | 180 | 210 | 156 |
◆KXX2-D620-D800 overall size and installation size
◆KXX2-D780 overall size and installation size
◎Wire connecting drawing
2P,3P,4P contaactor
KXX2-D115 till D620(coil LX1-F~)
KXX2-D115 till D620(coil LX4-F=)
KXX2-D115 till D620(coil LX4-F~)
KXX2-D115 till D245(coil LX9-F~)
KXX2-D800(coil LXB-F~/=)
KX2-D780~or =
◆wiring terminal wire connecting capacity:
Contactor model No. | Main circuit connecting capacity | Auxiliary and control circuit | ||||||
Copper line | Copper bar | Flexible wire | Rigid wire mm2 | |||||
PCS | Line section area mm2 | PCS | Size mm | 1 | 2 | 1 | 2 | |
KXX2-D115 | 1 | 95 | 2 | 20*3 | 2.5 | 4 | ||
KXX2-D150 | 1 | 120 | 2 | 25*3 | ||||
KXX2-D170 | 1 | 150 | 2 | 25*3 | ||||
KXX2-D205 | 1 | 185 | 2 | 32*4 | ||||
KXX2-D245 | 1 | 240 | 2 | 32*4 | ||||
KXX2-D300 | 1 | 240 | 2 | 30*5 | ||||
KXX2-D410 | 2 | 150 | 2 | 30*5 | ||||
KXX2-D475 | 2 | 240 | 2 | 50*5 | ||||
KXX2-D620 | / | / | 2 | 60*5 | ||||
KXX2-D800 | / | / | 2 | 60*5 | ||||
KXX2-D780 | / | / | 2 | 60*5 |
◎Application notice
Contactor silver contact after a certain times connecting and breaking operation, silver contact appearance will have slight singeing or nigrescence , this phenomenon won't affect application, no need polish it, otherwise will reduce silver contact life. But if singeing too serious to contact , then should use glossy file to file it slightly. If control voltage not in the range of (85%-110%Us)(as table 1), can communicate with manufacture for special order.
◎Order notice
Should indicate below details:
◆Contactor full model No. and description
◆Control coil voltage and frequency
◆Order quantity
For example: KXX2-D115 AC contactor 220V 50Hz 10 sets
◆Coil is quick-wear parts, can order separately, can indicate coil voltage specification code (as table 6) and quantity
For example: LX1-D170/110 10PCS
Product model No. | KXX2-D115/D150 | KXX2-D170/D205 | KXX2-D245 | KXX2-D300 |
Coil voltage specification and code | LX1-115/024 | LX1-170/024 | / | / |
LX1-115/048 | LX1-170/048 | LX1-245/048 | LX1-300/048 | |
LX1-115/110 | LX1-170/110 | LX1-245/110 | LX1-300/110 | |
LX1-115/220 | LX1-170/220 | LX1-245/220 | LX1-300/220 | |
LX1-115/380 | LX1-170/380 | LX1-245/380 | LX1-300/380 |
Product model No. | KXX2-D410 | KXX2-D475 | KXX2-D620/D800 | KXX2-D780 |
Coil voltage specification and code | / | / | / | / |
LX1-D410/048 | LX1-D475/048 | LX1-D800/048 | / | |
LX1-D410/110 | LX1-D475/110 | LX1-D800/110 | LX1-D780/110 | |
LX1-D410/220 | LX1-D475/220 | LX1-D800/220 | LX1-D780/220 | |
LX1-D410/380 | LX1-D475/380 | LX1-D800/380 | LX1-D7800/380 |
◆KXX2-D780 coil is 2PCS
◆DC coil is LX4-F^ special coil is LX9-F^