KXW1 series intelligent universal circuit breaker

0.1~50.0 USD
Min. Order: 100 Piece/Pieces
Payment Terms: L/C, T/T, WU
Supply Ability: 100000PCS/PER MONTH
Place of Origin: Zhejiang

Company Profile

Location: Wenzhou, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company, Agent
Main Products: Distribution Box, Low Voltage Switchgear Cabinet

Product Detail

Model No.: KXW1 400/6300
Means of Transport: Ocean, Air, Land
Type: Conventional
Poles Number: 4
Brand Name: CHKX
Frequence: AC50Hz
Rated working voltage: 690V or lower
Application: modern construction
Moulded case current Inm: 400A-6300A
Criteria: GB10963.1-2005
Pole: 3,4
breaking capacity grade: M,H
Rated Isolating voltage: 800V
Accessories: SD,OF,MX,MX+OFF,MV,MN,MV+MN.
Rated current: 63A,100A,225A,400A,630A,800A
Production Capacity: 100000PCS/PER MONTH
Packing: Neutral or customized
Delivery Date: 30 days or customized
Show

Product Description

KXW1 series intelligent universal circuit breaker

◎Application:

KXW1 series intelligent universal circuit breaker(hereinafter referred to as circuit breaker), apply to distribution network of AC50Hz, rated working voltage lower than 690V, rated current 400A-6300A, for distributing electric and protecting circuit and power apparatus from overload, undervoltage, short circuit, single phase earth fault etc damage, circuit breaker have intelligentized protection function, with high precision optional function, improved power supply reliability. With standard RS485 communication interface, have 4 remote function"remote testing""remote communication""remote control""remote adjust", to satisfy the request of cluster control center and automatic system.

This series circuit breaker have compact structure, high breaking capacity, no arc distance etc features. Circuit breaker can be isolation switch while it without intelligent trip mechanism and sensor.

◎Model No. and meaning:

KXW1 series intelligent universal circuit breaker

◎Acceptable working surrounding and installation criteria:

Surrounding max temperature can't exceed +40℃, min temperature can't lower -5℃, and average temperature can't exceed +35℃ in 24h;

Atmospheric relative humidity should lower than 50% when the temperature is +40℃, higher relative humidity is acceptable when the temperature lower than +40℃, max relative humidity can reach 90% when the temperature at +20℃, should have special policy in condensation condition which may caused by temperature changing;

The altitude of installation place should lower than 2000m, circuit breaker vertical gradient can't exceed 5°;

Pollution degree: III

Installation type: IV type: Rated working voltage lower than 390V circuit breaker and undervoltage trip mechanism, power supply transformer initial coil; III type: auxiliary circuit and control circuit

◎Circuit breaker structure introduction:

Fixed type circuit breaker consist of contact system, intelligent controller, handle operation mechanism, electric operation mechanism, mounting panel.

Drawer type circuit breaker consist of contact system, intelligent controller, handle operation mechanism, electric operation mechanism, mounting panel.

As a three dimensional arrangement, the circuit breaker have compact in structure and small in volume feature. Contact system is enclosed in isolating base, each group contact is a chamber, intelligent controller, handle operation mechanism, electric operation mechanism form three independent units in front it, convenient for maintaining.

Drawer type consist of plug in type circuit breaker and drawer base, plug in type circuit breaker in the rail of drawer base. Drawer type circuit breaker have three working position: Connect, test and separate, rotate handle to reach position change, three position indicate needle is in the cross beam of the drawer base.

Connect position: main circuit and secondary circuit power is connected

Test position: Main circuit disconnect by isolating panel, only secondary circuit is connected, can make some necessary testing operation;

Operate: Main circuit and secondary circuit is disconnected.

Drawer type circuit breaker have interlock device, circuit breaker closed while in connect position, it can't close in the middle of connect and test position.

◎Intelligent trip mechanism performance:

Intelligent trip mechanism have 3 types: L type(economic type), M type(standard type), H type(communicated type)

Have overload long delay time inverse time limit, short circuit short delay time inverse time limit(and definite time limit), short circuit instantaneous protection, asymmetric earth(null) fault protection etc four section protection characteristic; short circuit short delay time definite time limit protection, asymmetric earth(null) fault protection of L type is additional optional function.

Setting function: adopt code switch and dial switch to set(L type) or digital display and keypad to set(M,H type),

Indicating function: indicate circuit breaker working current, indicate every protection condition

Self-detecting function: surrounding temperature overheat self diagnosis, micro-controller inner CPU, ROM, RAM and I2C communication self detect.

Fault memory function: Remember trip fault current, delay operation time, fault type which caused by circuit fault.  

Thermal memory function: remember circuit or apparatus thermal condition which caused by overload and short circuit(reset after electric power off)

Test function: Simulate fault status of circuit trip and non trip testing

Additional optional function: Voltage meter function, load monitoring function, all overload alarm signal output function, MCR connect breaking and simulate trip protection function

H type intelligent trip mechanism besides has the M type all functions, have serial communication interface, can form master slaver structure LAN(local area network) system by communication interface, 1-2 sets computer as master station, several intelligent circuit breaker or other communication interface component as slaver station, the system can realize long distance four remote function to circuit breaker unit.

◎circuit breaker structure drawing:

KXW1 series intelligent universal circuit breaker

◎Circuit breaker rated sustained current changing in different surrounding temperature:

Inm

KXW1-2000(Table I)

KXW1-3200(Table II)

KXW1-6300(Table III)

In(A)

630

800

1000

1250

1600

2000

2000

2500

2900

3200

4000

4000

5000

6300

Surrounding

Temperature

(℃)

40

630

800

1000

1250

1600

2000

2000

2500

2900

3200

4000

4000

5000

6300

50

630

800

1000

1250

1600

2000

2000

2500

2900

3200

4000

4000

5000

6300

60

630

800

1000

1250

1600

2000

2000

2500

2900

3200

4000

4000

5000

6300

◎Circuit breaker user install copper bar requirement:

Inm

KXW1-2000(Table I)

KXW1-3000(Table II)

KXW1-6300(Table III)

In(A)

630

800

1000

1250

1600

2000

2000

2500

2900

3200

4000

4000

5000

6300

Thickness(mm)

5

5

5

5

5

5

5

5

10

10

10

10

10

10

Width(mm)

40

50

60

80

100

100

100

100

100

100

120

120

120

120

Root No.

2

2

2

2

2

3

3

4

4

4

4

6

6

6

Circuit breaker technical data and performance(Table I)

Model   No.

KXW1-630

KXW1-800

KXW1-1000

KXW1-1250

KXW1-1600

KXW1-2000

Rated   current(A)

630

800

1000

1250

1600

2000

Rated   working voltage(V)

690

690

690

690

690

690

Rated   isolating voltage(V)

1000

1000

1000

1000

1000

1000

Pole

3,4

3,4

3,4

3,4

3,4

3,4

Breaking   time(ms)

30

30

30

30

30

30

Switch   on time(ms)

60

60

60

60

60

60

Breaking   capacity

S

H

S

H

S

H

S

H

S

H

S

H

Rated   limit short circuit breaking capacity(kA)

400V

65

80

65

80

65

80

65

80

65

80

65

80

690V

50

50

50

50

50

50

50

50

50

50

50

50

Rated running   short circuit breaking capacity(kA)

400V

50

65

50

65

50

65

50

65

50

65

50

65

690V

50

50

50

50

50

50

50

50

50

50

50

50

Rated short   time resistant current (kA)

400V

50

50

50

50

50

50

50

50

50

50

50

50

690V

40

40

40

40

40

40

40

40

40

40

40

40

Intelligent   trip mechanism

Mechanical   life time

Keep   maintain

20000

20000

20000

20000

20000

20000

Without   maintain

10000

10000

10000

10000

10000

10000

Installation   type

Fixed   type

Drawer   type

Overall   size(mm) H*W*D

Fixed   type 3P

400*362*327

400*362*327

400*362*327

400*362*327

400*362*327

400*362*327

Fixed   type 4p

400*457*327

400*457*327

400*457*327

400*457*327

400*457*327

400*457*327

Drawer   type 3P

450*375*421

450*375*421

450*375*421

450*375*421

450*375*421

450*375*421

Drawer   type 4P

450*470*421

450*470*421

450*470*421

450*470*421

450*470*421

450*470*421

Weight(kg)

Fixed   type 3P

41

41

41

42.4

42.4

44.5

Fixed   type 4p

53

53

53

55.1

55.1

57.8

Drawer   type 3P

65.4

65.4

65.4

68

68

69.8

Drawer   type 4P

83.9

83.9

83.9

87.8

87.8

92.3

 

Circuit breaker technical data and performance(Table II)

Model   No.

KXW1-2000

KXW1-2500

KXW1-2900

KXW1-3200

KXW1-4000

Rated   current(A)

2000

2500

2900

3200

4000

Rated   working voltage(V)

690

690

690

690

690

Rated   isolating voltage(V)

1000

1000

1000

1000

1000

Pole

3,4

3,4

3,4

3,4

3,4

Breaking   time(ms)

30

30

30

30

30

Switch   on time(ms)

60

60

60

60

60

Breaking   capacity

S

H

S

H

S

H

S

H

S

H

Rated   limit short circuit breaking capacity(kA)

400V

80

100

80

100

80

100

80

100

80

100

690V

65

65

65

65

65

65

65

65

65

65

Rated running   short circuit breaking capacity(kA)

400V

65

65

65

65

65

65

65

65

65

65

690V

50

50

50

50

50

50

50

50

50

50

Rated short   time resistant current (kA)

400V

65

65

65

65

65

65

65

65

65

65

690V

50

50

50

50

50

50

50

50

50

50

Intelligent   trip mechanism

Mechanical   life time

Keep   maintain

20000

20000

20000

20000

20000

Without   maintain

10000

10000

10000

10000

10000

Installation   type

Fixed   type

Drawer   type

Overall   size(mm) H*W*D

Fixed   type 3P

400*422*327

400*422*327

400*422*327

400*422*327


Fixed   type 4p

400*537*327

400*537*327

400*537*327

400*537*327


Drawer   type 3P

450*435*421

450*435*421

450*435*421

450*435*421

450*550*421

Drawer   type 4P

450*550*421

450*550*421

450*550*421

450*550*421


Weight(kg)

Fixed   type 3P

48

48

59

59


Fixed   type 4p

61.6

61.6

76.7

76.7


Drawer   type 3P

75

75

90

90

93

Drawer   type 4P

95

95

117

117


 

Circuit breaker technical data and performance(Table III)

Model   No.

KXW1-4000

KXW1-5200

KXW1-6300

Rated   current(A)

4000

5200

6300

Rated   working voltage(V)

690

690

690

Rated   isolating voltage(V)

1000

1000

1000

Pole

3,4

3,4

3,4

Breaking   time(ms)

30

30

30

Switch   on time(ms)

60

60

60

Breaking   capacity




Rated   limit short circuit breaking capacity(kA)

400V

120

120

120

690V

85

85

85

Rated running   short circuit breaking capacity(kA)

400V

100

100

100

690V

75

75

75

Rated short   time resistant current (kA)

400V

100

100

100

690V

75

75

75

Intelligent   trip mechanism

Mechanical   life time

Keep   maintain

20000

20000

20000

Without   maintain

10000

10000

10000

Installation   type

Fixed   type




Drawer   type

Overall   size(mm) H*W*D

Fixed   type 3P




Fixed   type 4p




Drawer   type 3P


450*813*486

450*928*486

Drawer   type 4P

450*788*486

450*928*486

450*928*486

Weight(kg)

Fixed   type 3P




Fixed   type 4p




Drawer   type 3P


230

230

Drawer   type 4P

210

240

240

◎Over current protection and earth fault protection characteristic curve

Over current protection characteristic curve

 KXW1 series intelligent universal circuit breaker

Earth fault protection characteristic curve

 KXW1 series intelligent universal circuit breaker

◎Load monitoring protection characteristic curve

Load monitoring way1:2 load limit value

 KXW1 series intelligent universal circuit breaker

Load monitoring way2:1 load limit ,1 load doublication

KXW1 series intelligent universal circuit breaker

◎Intelligent trip mechanism parameter:

Intelligent trip mechanism

L(economic type)

M(standard   type)    H(communicated type)

Long time delay

Long time delay setting current Ir1(s)

(0.4-1)In(7 degree)+OFF(exit position)

(0.4-1)In(≤2% degree   difference, minimum 160A)+OFF(exit position)

Long time delay setting time TL(s)

30

60

120

240

15

30

60

120

240

480

Operation time TL=(1.5Ir1)* (1.5Ir1)/working current I*TL

I=1.5Ir1

30

60

120

240

15

30

60

120

240

480

I=2.0Ir1

16.9

33.7

67.5

135

8.4

16.9

33.7

67.5

135

270

I=7.2Ir1

1.3

2.6

5.2

10.4

0.65

1.3

2.6

5.2

10.4

21

Precision

±15%

±10%

Thermal memory(30min,can be cleared after power off)

Standard +OFF (exit position)

Standard +OFF (exit position)

Short time delay

Short time delay setting current Ir2

(3-10)In +OFF(exit position)

(0.4-15)In(≤4% degree   difference)+OFF(exit position)

Short time delay setting time Ts(s)

0.2

0.4

0.1

0.2

0.3

0.4

While >8Ir1 setting time   limit operation time(ms)

200

400

60

160

255

340

While≤8Ir1 inverse time   limit operation time(ms)

Non function

Ts=(8Ir1)2*Ts/I2

Precision

±15%

±10%

Thermal memory(15min,can be cleared after power off)

Non function

Standard +OFF (exit position)

Short circuit instantaneous   

Short circuit instantaneous setting current Ir3

(3-10)In,(7-14)In,(10-20)In

1.0In-50Ka(Table 1),75kA(Table 2),100kA(Table III) degree   difference≤4%

OFF(exit position)

Standard +OFF (exit position)

Standard +OFF (exit position)


Earth protection

Earth protection setting current Ir1

(0.2-0.8) In+ OFF(exit position)

(0.2-0.8) In+ OFF(exit position) ≤2% degree difference min160A, max 2400A

Earth protection setting time TG(s)

0.2

0.4

0.6

0.8

0.1

0.2

0.3

0.4

Precision

±15%

±10%

Current indicate

Current indicate way

Current panel light pillar indicate

Digital current meter indicate

Display

40%-100%+ overload indicate ±3%

L1-L2-L3-MAX±3%















Intelligent trip mechanism parameter:

Intelligent trip mechanism

L(economic type)

M(standard   type)    H(communicated type)

Load monitoring

2 load limit value

Ic1


(0.2-1)In(≤20% degree   difference, minimum 160A)

Ir1


0.5TL, T=(1.5Ir1)* (1.5Ir1)/*Tr-I2 in 1.5Ic1

Ic2


(0.2-1)In(≤20% degree   difference, minimum 160A)

Ir2


0.5TL, T=(1.5Ir1)* (1.5Ir1)/*Tr-I2 in 1.5Ic1

1 load limit value

1 load doublication

Ic1


(0.2-1)In(≤20% degree   difference, minimum 160A)

Ir1


0.5TL, T=(1.5Ir1)* (1.5Ir1)/*Tr-I2 in 1.5Ic1

Ic2


(0.2-1)In(≤20% degree   difference, minimum 160A)

Ir2


Fixed 60s

Precision


±10%

Thermal memory(30min, can be cleared after power off)


Standard +OFF(exit position)

Pre-alarm

Pre-alarm setting current IrP

Ir1

Ir1

Alarm characteristic(1.05-1.20)Irp

Alarm

Alarm

Precision

±10%

±10%

Thermal memory(30min, can be cleared after power off)

Standard +OFF(exit position)

Standard +OFF(exit position)

Voltage indicate

Testing

Instantaneous trip

Can simulate all kinds fault current to switch off(trip or non   trip)

Fault output

Self diagnosis

Inner overheat, controller non working power supply, MCU run   abnormally, switch cabinet panel display and alarm contact output

Output fault type

Ir1, Ir4,self-diagnosis, OCR

Ir1, Ir2, Ir3, Ir4, Ic2 , self-diagnosis, OCR

RS485 communicate interface



RS485 communicate interface


Only H type adopt it (according to user requirment)

◎Circuit breaker mechanical interlock device

KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

◎Inner accessories and function:

Undervoltage trip mechanism

KXW1 series intelligent universal circuit breaker

Cut off circuit breaker instantaneously while power supply voltage reduce to 35%-70% of the rated voltage; can't switch on if coil without excitation, only can switch on after voltage recover to 85% Ue

 

Rated working voltage(Ue)

AC400V

AC230V

AC220V

Power requirement

36VA

24VA

24W

Breaking time

Instantaneous, time delay 1,3,5s±10%

Shunt trip mechanism

KXW1 series intelligent universal circuit breaker

For circuit breaker long distance switch off; reliable operation range 70%-11%Us.

Rated control voltage Us

AC380V

AC220V

DC220V

Power requirement

24VA

24VA

24W

Instantaneous current

0.7A

1.3A

1.3A

Breaking time

Shorter than 30ms

Auxiliary contact

KXW1 series intelligent universal circuit breaker

Have 4 normally open 4 normally close contact; special specification should communicate with manufacturer.

Rated working voltage(Ue)

AC380V

AC220V

DC220V

Conventional thermal current Ith

6A

6A

6A

Usage

AC-15

300VA

300VA

-

DC-13

-

-

60W

Closed electric magnet

KXW1 series intelligent universal circuit breaker

Make operation mechanism energy storage spring instantaneous release after finished energy storage, circuit breaker close rapid, reliable operation range 85%-110% Us

 

Rated control voltage Us

AC380V

AC220V

DC220V

Power requirement

24VA

24VA

24W

Instantaneous current

0.7A

1.3A

1.3A

Switch on time

Shorter than 70ms

Electric motor operation mechanism

KXW1 series intelligent universal circuit breaker

For circuit breaker electric energy storage and automatic re-storage energy function; circuit breaker have manual energy storage function; reliable operation range 85%-110% Us.

Rated control voltage Us

AC380V

AC220V

DC220V

Power requirement

KXW1-2000

85VA

85VA

85W

KXW1-3200

110VA

110VA

110W

KXW1-6300

150VA

150VA

150W

Energy storage time

Short than 5ms

Sealing Frame:

KXW1 series intelligent universal circuit breaker

Fixed in the cabinet door, elegant and practical, with sealing function, protection level can reach IP405; have drawer type frame (MK1) and fixed type frame(MK2) 2 types

◎Secondary wire connecting drawing

Trip mechanism L type and M type basic function:

 KXW1 series intelligent universal circuit breaker

Trip mechanism L type with accessory function:

 KXW1 series intelligent universal circuit breaker

Trip mechanism H type and M type with additional function:

 KXW1 series intelligent universal circuit breaker

Trip mechanism M type with 6 normally open 6 normally close auxiliary contact:

KXW1 series intelligent universal circuit breaker

◎Communicated type networking diagram:

KXW1 series intelligent universal circuit breaker

Wire connecting explain:

1#,2#  auxiliary power supply input terminal

3#,4#,5# fault trip contact output terminal

6#,7# circuit breaker status first group auxiliary contact output terminal

8#,9# circuit breaker status second group auxiliary contact output terminal

10#RS485 communicate P terminal (simplex) remote communicate (only H type have this function)

11# RS485 communicate N terminal (simplex) remote communicate (only H type have this function)

12#,13# controller first group signal contact output

14#,15# controller second group signal contact output

16#,17# controller third group signal contact output

18#,19# controller forth group signal contact output

20# protect ground

21#,22#,23#,24# voltage display input terminal

25#,26# circumscribe mutual inductor input terminal

If F,X,M different control power supply voltage should connect different power supply

For avoid shunt trip mechanism and switch on electric magnet unnecessary damage, please tandem connect separately 1 group normally open(shunt) and normally close(switch on) contact when user use it, it not be connected when leave factory;

Terminal 35# can connect power supply(automatic pre-energy storage) directly, also can tandem connect normally open button then connect power supply(manual pre-storage energy);

Terminal 6#,7# can output normally close contact if customer need it;

 When intelligent controller working power supply is DC power supply, need add DC power supply module, power supply module 2 output terminal separately relevant connect secondary wiring terminal 1#(+), 2#(-).

Controller 4 groups independent signal contact output, its function can set by programming unit or special way, can provide total 10 types signal output function, the function and code is as below:

1.Short circuit instantaneous fault trip alarm; 2. ground or electricity leakage fault trip alarm; 3. Electricity unbalance fault trip alarm; 4.short circuit short time delay fault trip alarm; 5.Overload long time delay fault trip alarm; 6.Fault trip alarm; 7. Load monitoring 1 unload output; 8. Load monitoring 2 unload output; 9. System self diagnosis fault alarm; 10. Electric network fault status alarm.

Controller 4 groups contact function is default setting status while leave factory if customers no special request.

◎Controller setting

Controller long time delay current setting: Press "clear" button, then press "set" button till long time delay status indicate light on, display long time delay leave factory current setting value, normally is "In", current setting range is 0.4-10In, can press "+" "-" button as required, will have ﹤2% interval increasing or decrease by each button pressing, till reach closest current requirement. Then press "storage" button one time , storage indicate light on and then off, means long time delay current setting value finish storage.

Long time delay time setting: Press "set" button after finish long time delay current setting, long time delay time status indicate light on, display long time delay time leave factory setting value, can press "+" "-" button as required, till reach closest time requirement. Then press "storage" button one time, storage indicate light on and then off, means long time delay time setting value finish storage. Load monitor, short time delay, instantaneous, earth fault etc protection operation value setting and operation time, setting method as above, only relative indicate light different. Earth time setting on "OFF" position, means fault status, earth only alarm non trip; instantaneous setting on "OFF" position, means cancel this protection; controller lock button function automatic and into fault treatment state if have fault signal during setting process.

Those controller parameter, can't cross set. Controller protection priority as below: long time delay﹤short time delay﹤instantaneous. About doublication switch, ILC2 setting value less than ILC1, after finish set controller parameter, then press "clear" button one more time, or power off reset, makes controller in running state.

◎Controller test:

After finish set controller parameter, before circuit breaker working, user can test circuit breaker all protection function, controller testing have trip/non-trip option, press "trip" button to test, circuit breaker breaking, press "non-trip" button to test, then won't send trip signal, circuit breaker won't trip.(Note: L type product only have trip test, press "test" button, then controller will send instantaneous operation signal, circuit breaker breaking)

Overload testing, press "set" button to long time delay status, check overload set value then to other current status, press "+" "-" button, adjust current to >1.3Ir1 current, press test button into overload testing status, controller according to inverse time limit rule to time delay operate, and indicate fault type and testing status. Other characteristic testing similar as it, press "clear" after finish testing then into normal working status, also must need press mechanical "reset" button, to close circuit breaker.

◎Controller other usage rule:

Controller in setting , testing status, if not press button in 1min, will clear automatically and into working status, if have fault status, will lock button function and into fault treatment state.

a.        Set test:

After pressing controller "clear" button, press "set" button continuously(under fault free condition), display circularly all status and relative setting current and time value. Please press "clear" button after finish testing (if not press button in 1min, will clear automatically and into working status)

b.        Electric network working current and voltage test

After pressing controller "clear" button, press "select 1" button ("select" button) continuously(under fault free condition), display circularly all working current value and earth current value, normally display max current; press "select 2" button continuously , display circularly all voltage value, normally display max voltage

c.        Reset

Should press controller "clear" button before circuit breaker switch on, let circuit breaker into normal working condition, then press mechanical "reset" button to switch on circuit breaker.

◎Note: Controller choose M type, leave factory setting range as below:

Long time delay Ir1 set in 1.0In, 1.5Ir1 operation time setting is 15s

Short time delay Ir2 set slightly higher than 8Ir1, definite time limit is 0.4s

Instantaneous Ir3 set in 12In

Earth fault Ir4 set in 0.4In, operation time set "OFF" only display and circuit breaker not disconnect.

◎Intelligent controller panel structure:

KXW1 series intelligent universal circuit breaker

1-Reset button: Should press reset button after circuit breaker trip to switch on, otherwise circuit breaker can't be closed

2-Current(voltage) : display time, can display current(voltage) or time value

3-"select" button: can display circularly all current(voltage) value in normal working condition, fault status or fault detect status display circularly fault current or time value.

4-LED indicator: can indicate all status and classification

5-Clear button: Must press this button after controller setting, fault testing or before circuit breaker switch on

6-Set button: For test or setting all kind protection characteristic current or time. Pressing this button would indicate circularly all status

7-Fault detect button: After clear controller, press this button can display and indicate last fault status and fault current or time value. Can press "select" button to detect fault current or time circularly.

8-Trip, non-trip button: For testing

9-Storage,+,- button: For setting current or time

Ir4-Earth protection current setting value

Ir1-Long time delay current setting value

Ir2-Short time delay current setting value

Ir3-Instantaneous current setting value

tG- Earth protection current setting value

tL-Long time delay current setting value

ts-Short time delay current setting value

◎Intelligent controller panel structure:

 KXW1 series intelligent universal circuit breaker

1-Reset button: If need re-close circuit breaker, should press this button after circuit breaker fault or trip testing.

2-Load indicate: Display overload long time delay current

3-Long time delay, short time delay, time delay, earth fault current setting button, rotary knob calibration value can set all protection current

4-Fault indicator: indicate fault type

5-Long time delay overload protection time setting button: dial switch position to adjust time

6-Short time delay protection time setting button: Dial switch position to adjust time.

7-Earth fault protection time setting button: dial switch position to adjust time

8-Clear button: Must press this button after controller setting, testing and default, let controller into normal working status.

9-Fault testing button: Press this button after circuit breaker fault tripping, can indicate fault tripping reason. Have fault memory function after cutoff electricity

10-Test button: Can detect cooperation condition between controller and circuit breaker

L type setting method:

1.        Long time delay setting:

a.        Dial Ir1 switch setting current from 0.4-1In

b.        Dial tL button setting time 30s,60s,120s,240s

c.        Dial Ir1 switch to OFF position means exit this function

2.        Short time delay setting

a.        Dial Ir2 switch setting current from 3-10In

b.        Dial ts button setting time 0.2s,0.4s,

c.        Dial Ir2 switch to OFF position means exit this function

3.        Instantaneous setting

a.        Dial Ir3 switch setting current from 3-10In or 10-20In

b.        Dial Ir3 switch to OFF position means exit this function

4.        Earth fault protection setting

a.        Dial Ir4 switch setting current from 0.2-0.8In

b.        Dial tG button setting time 0.2s,0.4s,0.6s,0.8s

c.        Dial Ir4 switch to OFF position means exit this function

5.        Controller into working condition: should press clear button after finish adjusting all controller parameter   

◎Circuit breaker overall and installation size

KXW1-2000 fixed type circuit breaker overall and installation size

 KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

KXW1-2000 drawer type circuit breaker overall and installation size

 KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

KXW1-3200 fixed type circuit breaker overall and installation size

 KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

KXW1-3200 drawer type circuit breaker overall and installation size

 KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

KXW1-4000 drawer type circuit breaker overall and installation size

 KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

KXW1-5000 drawer type circuit breaker overall and installation size

 KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

KXW1-6300 drawer type circuit breaker overall and installation size

 KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

Frame size and installation hole boring drawing:

KXW1 series intelligent universal circuit breaker

KXW1 series intelligent universal circuit breaker

 

Moulded case rated current (Inm)(A)

a(mm)

b(mm)

c(mm)

2000

306

345

0

3200,4000/3P

366

405

0

4000/4P

306

345

20

6300

366

405

20