KXA series modularization socket apply to household residence hotel airport wharf etc place for distribution system

0.1~50.0 USD
Min. Order: 100 Piece/Pieces
Payment Terms: L/C, T/T, WU
Supply Ability: 100000PCS/PER MONTH
Place of Origin: Zhejiang

Company Profile

Location: Wenzhou, Zhejiang, China (Mainland)
Business Type: Manufacturer, Trading Company, Agent
Main Products: Distribution Box, Low Voltage Switchgear Cabinet

Product Detail

Model No.: KXA 1/3
Means of Transport: Ocean, Air, Land
Application: Residential / General-Purpose
Grounding: Others
Type: Others
Brand Name: CHKX
Rated Voltage: 230V/400V
Rated Current: 10A,16A,25A
Frequence: AC50Hz/60Hz or lower
Rated working voltage: 230V/400V or lower
Application: modern construction
Function: overload protection or short circuit protection
Criteria: IEC60884-1,GB2099
Specification: Single phase 2 holes,Single phase 3 holes,Three phases 4 holes
guide line section area(mm2): 10,16
Model NO.: KXA1,KXA3
Width: 18,36,45,54,72
Rated current: 10,16,25
Production Capacity: 100000PCS/PER MONTH
Packing: Neutral or customized
Delivery Date: 30 days or customized
Show

Product Description

KXA series modularization socket:

Application:

KXA series modularization socket apply to household residence, hotel , airport, wharf etc place for distribution system, can combine with DZ47 series circuit breaker, DZ30 series circuit breaker, C65N series circuit breaker and lighting distribution box etc devices, also can be installed into other complete apparatus.

This product according to IEC60884-1,GB2099 criteria

Model No. and meaning:

KXA series modularization socket apply to household residence hotel  airport wharf etc place for distribution system

Main technical parameter:

MODEL NO.

Specification

Rated current(A)

Rated voltage(V)

guide line section area(mm2)

KXA1

KXA3

Single phase 2 holes

10,16

230

≤10

Single phase 3 holes

10,16,25

230

≤16

Three phases 4 holes

16,25

400

≤16

 

MODEL NO.

Rated voltage(V)/current(A)

Width

Occupy circuit amount

KXA1/KXA3-10/22 two holes

220V/10A

18

1

KXA1/KXA3-10/34 three holes

220V/10A

36

2

KXA1/KXA3-16/34 four holes

220V/16A

36

2

KXA1/KXA3-25/35 four holes

380V/25A

45

2.5

KXA1/KXA3-16/46 four holes

380V/16A

54

3

KXA1/KXA3-25/48 four   holes

380V/25A

72

4

Overall and installation size drawing:

KXA series modularization socket apply to household residence hotel  airport wharf etc place for distribution system

KXA series modularization socket apply to household residence hotel  airport wharf etc place for distribution system

KXA series modularization socket apply to household residence hotel  airport wharf etc place for distribution system


 KXM1-63 miniature circuit breaker MCCB MCB 1P-2P-3P-4P 1A to 63A

Bimetal:   Actually, it contains three metals iron, copper, cadmium, galvanized. Three metals with different coefficients of thermal expansion, bending cause thermal Pick reflect and making the breaker disconnect. This is the most import parts of the circuit breaker.  The Bimetal is the use of different materials under different breaker amperage.

Coil:  It's the important parts for the reaction of the Magnetic Trip. It's always 9 ring. As a matter of fact, the number of Coil with Different Amperage.For example, 1A reaches over 100 ring, and 63A is used to 56 ring. The Diameter Thickness is also different for Amperage.

Action Contactor(Sliver Point): It's the main point for the Reaction of Trip. Under normal conditions, keeping closed. When overload and short circuit, It will be breaking.

Arc Chute: Playing a role in destroying the arc. Generally tend to produce a large number of Moving and Static Contactor from the contactor, arc, even emerge spark.