user login

Dual 85W Output AC DC LED Power Supply Isolated RID-85 Series

Place of Origin: Zhejiang

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Outdoor Full Color LED Display, Indoor Full Color LED Display, Double Sided LED Sign

Product Detail

Model No.: RID-85 Dual Output Switching Power Supply Isolated

Product Description

85W Dual Output AC DC LED Power Supply Isolated RID-85 Series

 

 

 

G3 Series RD-85 Enclosed Switching Power Supply Features:

1. Isolated output & GND for CH1,CH2
2. Universal AC input / Full range
3. Protections: Short circuit / Overload / Over voltage
4. Cooling by free air convection
5. LED indicator for power on
6. 100% full load burn-in test
7. All using 105 celsius long life electrolytic capacitors
8. Withstand 300VAC surge input for 5 second
9. High operating temperature up to 70 celsius
10. Withstand 5G vibration test
11. High efficiency, long life and high reliability
12. 3 years warranty

 

Meanwell G3 Series AC to DC Switching Power Supplies:

RS-15 / RS-25 / RS-35 / RS-50 / RS-75 / RS-100 / RS-150

RD-35 / RD-50 / RD-65 / RD-85 / RD-125

RID-50 / RID-65 / RID-85 / RID-125, RT-50 / RT-65 / RT-85 / RT-125

RQ-50 / RQ-65 / RQ-85 / RQ-125

 

 

Quick Details:

85W - Dual Output
Model No. Output Tol. R&N Effi.
RD-125A

 5V, 2.0~15A 

 

 12V, 0.5~10A

±5%

 

±7%

80mV

 

120mV

82%
RD-125B

 5V, 2.0~10A

 

 24V, 0.4~5.0A

±5%

 

±7%

80mV

 

120mV

86%

 

General Specifications:

Model No. RS-100
RD/RID/RT/RQ-85
AC input voltage range 88~264VAC, 125~373VDC
AC inrush current (max.) 40A at 230VAC
DC adjustment range

±10% by potentiometer for single output; 

CH1 -5%~+10% by potentiometer for multiple output

Overload protection 110%~150% hiccup mode, auto-recovery (150% ~190% for RID-125-1205/2405)
Over voltage protection 115%~135% rated output voltage, hiccup mode, auto-recovery
Withstand voltage I/P - O/P: 3kVAC, I/P - FG: 1.5kVAC, O/P - FG: 0.5kVAC, 1 minute
Working temperature -25~+70°C (refer to the derating curve for different models)
Vibration

10~500Hz, 5G 10min. /1 cycle, period for 60 min. 

each along X, Y, Z axes

Safety standards UL60950-1, TUV EN60950-1 approved
EMC standards

EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, 

EN61000-6-2 (EN50082-2) (35~150W)

Connection Terminal block for input and output
Dimension (LxWxH)(mm) 159x 97x 38
Case No. 901C
Packing 24pcs /15.4kg

 

NOTE:

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 celsius of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
 

 

 

 

Meanwell AC to DC Switching Power Supply of Our Product Range:

G3 Series

NE Series

SE Series

LRS Series

 

Your inquiries are highly welcome! 

 

Post Buying Request