Place of Origin: | Zhejiang |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Outdoor Full Color LED Display, Indoor Full Color LED Display, Double Sided LED Sign |
Model No.: | RID-85 Dual Output Switching Power Supply Isolated |
---|
85W Dual Output AC DC LED Power Supply Isolated RID-85 Series
G3 Series RD-85 Enclosed Switching Power Supply Features:
1. Isolated output & GND for CH1,CH2
2. Universal AC input / Full range
3. Protections: Short circuit / Overload / Over voltage
4. Cooling by free air convection
5. LED indicator for power on
6. 100% full load burn-in test
7. All using 105 celsius long life electrolytic capacitors
8. Withstand 300VAC surge input for 5 second
9. High operating temperature up to 70 celsius
10. Withstand 5G vibration test
11. High efficiency, long life and high reliability
12. 3 years warranty
Meanwell G3 Series AC to DC Switching Power Supplies:
RS-15 / RS-25 / RS-35 / RS-50 / RS-75 / RS-100 / RS-150
RD-35 / RD-50 / RD-65 / RD-85 / RD-125
RID-50 / RID-65 / RID-85 / RID-125, RT-50 / RT-65 / RT-85 / RT-125
RQ-50 / RQ-65 / RQ-85 / RQ-125
Quick Details:
85W - Dual Output | ||||
Model No. | Output | Tol. | R&N | Effi. |
RD-125A |
5V, 2.0~15A
12V, 0.5~10A |
±5%
±7% |
80mV
120mV |
82% |
RD-125B |
5V, 2.0~10A
24V, 0.4~5.0A |
±5%
±7% |
80mV
120mV |
86% |
General Specifications:
Model No. | RS-100 RD/RID/RT/RQ-85 |
AC input voltage range | 88~264VAC, 125~373VDC |
AC inrush current (max.) | 40A at 230VAC |
DC adjustment range |
±10% by potentiometer for single output; CH1 -5%~+10% by potentiometer for multiple output |
Overload protection | 110%~150% hiccup mode, auto-recovery (150% ~190% for RID-125-1205/2405) |
Over voltage protection | 115%~135% rated output voltage, hiccup mode, auto-recovery |
Withstand voltage | I/P - O/P: 3kVAC, I/P - FG: 1.5kVAC, O/P - FG: 0.5kVAC, 1 minute |
Working temperature | -25~+70°C (refer to the derating curve for different models) |
Vibration |
10~500Hz, 5G 10min. /1 cycle, period for 60 min. each along X, Y, Z axes |
Safety standards | UL60950-1, TUV EN60950-1 approved |
EMC standards |
EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2) (35~150W) |
Connection | Terminal block for input and output |
Dimension (LxWxH)(mm) | 159x 97x 38 |
Case No. | 901C |
Packing | 24pcs /15.4kg |
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 celsius of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
Meanwell AC to DC Switching Power Supply of Our Product Range:
G3 Series
NE Series
SE Series
LRS Series
Your inquiries are highly welcome!