Place of Origin: | Zhejiang |
---|
Location: | Guangzhou, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Portable Meter Tester, Energy Meter Calibrator, Reference Standard Meter |
Model No.: | LP-2 |
---|
Output Current 0 ~ 50 Ampere Load Box For Power Cord Flexing Tester 6 Workstations
Product information:
This device is designed according to the relevant technical requirements of IEC, UL, and related technical requirement of national standards. It is applied to test of current power cords, cables and electrical material whose tested requirements of the current are under 50A. Only in the test of current can it test 2 samples (LP-1) or 6 samples (LP-2). The output voltage of the circuit can be adjustable.
Technical parameters:
Input voltage:AC220V±5%, 50Hz or AC110V±5%, 60Hz
Output current: 0 ~ 40A is arbitrary adjustable
Output voltage: 12V
Test station: Six stations
Ammeter Accuracy: ±1
Connecting wire: 7PIN Aviation wire
Environment temperature: -10~50
Input voltage | AC220V±5%, 50Hz or AC110V±5%, 60Hz |
Output current | 0 ~ 40A is arbitrary adjustable |
Output voltage | 12V |
Test station | Six stations |
Ammeter Accuracy | ±1 |
Connecting wire | 7PIN Aviation wire |
Environment temperature | -10~50 |
The load box is specially made to work with power cord flexing tester, suitable for testing the power cords which current are under 50A at the low voltage heavey current circuit.