I.Features

Safety regulations for CT/PT Analyzer application

 

  • All technical index should keep in work condition before testing with Analyzer.

  • Please follow associated international standards in a special application.

  • Forbid high voltage or high current connected to CT/PT Analyzer directly.

  • All tests need to follow procedure in user manual.

  • It is forbid to open the box of CT/PT Analyzer. Otherwise, the quality assurance will be invalid.

  • It is forbid to update or extend the tester without manufacturer authorization.

  • Please use the original accessories for Analyzer.

  • It is forbid to cut off test connection before LED indicator light is OFF. 

  • Please connect Analyzer to ground with grounding cable in no laboratory application.

  • Please confirm that one terminal of sample CT primary connected to ground.

  • Do not run Analyzer in extreme moist condition.

  • Please confirm that all terminals connected to Analyzer have no voltage. All voltage outputs are from CT/PT Analyzer.

  • Please confirm that voltage had been injected to CT secondary winding in CT test. Otherwise, CT/PT Analyzer will be damaged possibly.

  • Please confirm that voltage had been injected to PT primary winding in PT ratio test. Otherwise, CT/PT Analyzer will be damaged possibly.

  • The ratio error and phase angle error test is valid for electromagnetic voltage transformer only. It can not applied in CVT test.

  •  

    II.CT PT Analyzer technical index

     

    Tests for Current Transformer:

  • Excitation curve and parameters test

  • Turns ratio test

  • Ratio and phase error test

  • Polarity mark check

  • Winding resistance measurement

  • Secondary loop burden measurement

  • Error line curve test for protection CT

  • Transient CT parameters test

  • CT nameplate guess

  • Saturation hysteresis loop curve measurement

  • Tests for Voltage Transformer:

  • Turns ratio test

  • Ratio error and phase angle error test

  • Polarity test

  • Secondary burden test

  • Winding resistance test

  • Applications of CT/PT Analyzer:

  • CT nameplate check

  • CT parameters check in work burden

  • CT transient parameters analysis

  • CT ratio and phase error calibration

  • PT routine test

  •  

    III.Technical Index

  • Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13

  •  Power supply: AC220V±10%, 50/60Hz±10%

  • Voltage output: 0.1~180V (AC)

  • Current output: 0.001~5A(RMS)

  • Power output: 500VA

  • Maximum knee voltage measurement: 45KV

  • Current measurement:Range: 0~10A (automatically change range in 0.1/0.4/2/10A)  ;Error: <±0.1%+0.01%FS

  • Voltage measurement:Range: 0~200V (automatically change range in 1V/10V/70V/200V) ;Error: < ±0.1%+0.01%FS

  • Turns ratio measurement:Range:1~35000

    1~2000     error<0.05%

     

    2000~5000  error<0.1%

     

    5000~35000  error<0.2%

  • Phase measurement: error: ±2min; resolution: 0.01min

  • Winding resistance measurement: Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)

     Error: < 0.2%RDG+0.02%FS

     

    Maximum resolution: 0.1mΩ

  • Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree

  • CT Secondary burden: Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)

     

    Error: <0.2%RDG+0.02%FS 

     

    Maximum resolution: 0.001ohm

  • PT Secondary burden:

  • Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)

  •  

    Error :<0.2%RDG+0.02%FS 

     

    Maximum resolution: 0.1ohm

  • PT ratio measurement:Range: 1~35000 

    1~10000 error<0.1%

     

    10000~35000 error<0.2%

  •  PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%

  • PT phase angle measurement: maximum error < 3min

  • Make evaluation for test results according to selected standards

  •  Make word report for test result

  • Make word reports one time for multi-group test records on the PC

  • Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test

  • Compare excitation curves with saved excitation curves in the same window

  • Memory capacity: >1000 groups test results 

  • Working condition: temperature: -10℃~50℃; moist: ≤90%

  • Size: 485mm×356mm×183mm

  • Weight: <15kg 