Place of Origin: | Zhejiang |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | AC Frequency Drives, Low Voltage Variable Frequency Drive, Solar Variable Frequency Drive |
Model No.: | AD100 |
---|
Bulit-In Simple Emc Filter Low Voltage Variable Frequency Drive Track-Mounted Design
Quick Detail:
Specifications:
Project |
Specifications |
||
Power input |
Rated input voltage (V) |
Single-Phase 220V(-15%+30%) 3-phase 220 V (-15%+30%) 3-phase 380 V (-15%+30%) |
|
Rated input current (A) |
See table 2-1 |
||
Rated input frequency(Hz) |
50Hz/60Hz,tolerance±5% |
||
Power output |
Applicable motor(kW) |
See table 2-1 |
|
Rated output current(A) |
See table 2-1 |
||
The maximum output voltage(V) |
0rated input voltage, error<±3% |
||
The maximum output frequency(Hz) |
0.00600.00 Hz,unit0.01Hz |
||
Control characteristics
|
V/f patterns |
V/f control Sensor-less vector control 1 |
|
Speed range |
1:50 (V/f control) 1:100 (sensor-less vector control 1) |
||
Speed accuracy |
±0.5% (V/f control) ±0.2% (sensor-less vector control 1 ) |
||
Speed fluctuation |
±0.3% (sensor-less vector control 1 ) |
||
Torque response |
< 10ms (sensor-less vector control 1 ) |
||
Starting torque |
0.5Hz: 180% (V/f control, sensor-less vector control 1) |
||
Basic functions
|
Carrier frequency |
0.7kHz16kHz |
|
Overload capability |
G Model:150% Rated Current 60s,180% Rated Current 10s,200% Rated Current 1s. |
||
Torque boost |
Automatic torque boostManual torque boost 0.1%30.0% |
||
V/F Curve |
Three ways:Three ways: straight; multi-point type; N Th-type V / F curve(1.2 Th -type,1.4 Th -type,1.6 Th -type,1.8 Th -type,2 Th -type) |
||
Acceleration and deceleration Curve |
Line or curve acceleration and deceleration mode. Four kinds of acceleration and deceleration time,Ramp Time Range :0.06000.0s |
||
DC brake |
DC brake start frequency: 0.00600.00Hz DC brake time:0.0s10.0s DC brake current:0.0%150.0% |
||
Basic functions
|
Jog brake |
Jog frequency range:0.00Hz50.00Hz. Jog deceleration time: 0.0s6000.0s. |
|
Simple PLC,Multi-speed |
Through the built-in PLC or control terminal to achieve up to 16 speed running |
||
Built-in PID |
Facilitate the realization of process control loop control system |
||
Automatic voltage adjustment(AVR) |
When the grid voltage changes, can automatically maintain a constant output voltage |
||
Fast current limit function |
Minimize over current fault protection inverter running |
||
Over voltage Over current |
System automatically limits of current and voltage during operation to prevent frequent |
||
Run
|
Command source |
Given the control panel, control terminal, serial communication port given. |
|
Frequency given
|
Sevkeinradlswoafysfrtoeqsuweintcchy sources: digital setting, keyboard potentiometer setting, analog Voltage, given analog current reference pulse is given, the serial port is given, multi-speed given, PLC is given, the process PI D reference. There are several ways to switch |
||
Input terminal
|
5Switch input terminals, one way to make high-speed pulse input. 2-channel analog inputs,1-way voltage and current options,1- way to support input |
||
output terminal
|
1-way switch output terminal 1 relay output terminals 1 analog output terminal, and optional voltage and current. |
||
Protection function |
Provide fault protection dozen:Overcurrent,Overvoltage,Undervoltage,Overtemperature,Overload Etc Protection. |
||
Display and keyboard |
LED Display |
||
Display and keyboard Environment |
|