3 Phase Digital Energy Meter / Standard Source Output Large Current , High Volatge

Place of Origin: Zhejiang

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Energy Meter Calibrator, Digital Panel Meters, Multifunction Power Meter

Product Detail

Model No.: AT6025C

Product Description

 

3 Phase Digital Energy Meter / Standard Source Output Large Current , High Volatge

 

        

  • Accuracy :U, I, P, Kwh : ±0.05%; Q, Kvarh : ±0.1%;
  • U, I, P stability : 0.01%RG/3min, AC Voltage and AC Current distortion : ≤0.2%;
  • With OCXO daily error of energy meter can be detected;
  • 7" color touch screen, interface friendly, easy to operate;
  • Equipped with RS232 & Ethernet interface, AT6025C can be operated either stand-alone, or controlled by PC;
  • Current scope: Min. 0.05A, Max. 100A(Max output 120A); Voltage 57.7V-380V;
  • Export 2nd-63rd harmonics, and measure & analyze the harmonics;
  • Automatically or single-step manually test basic error, Creeping, start, standard deviation of single/three phase energy meter, besides, automatically testing can be self-defined by user;
  • Automatic Calibration System can be customized according to customer's requirements;
  • Exchange the testing settings and testing records thru U disk(or SD card);
  • Remotely updating online, easily achieve software updating;
  • Equipped with barcode gun interface, parameters of tested meters can be easily scanned in;
  • Communicate with tested meters thru RS485, Ethernet, RS232;
  • Self-protection, alarming and displaying overload location for equipment output overload, Voltage short-circuit, Current open-circuit;
  • Self-diagnosis for amplifier failure and internal module communication failure;
  • Test 3 energy meters with the same model type at one time
  • Test energy meters with the accuracy of Class 0.2 and below (Class 0.05 equipment);

 

 

Product Profile:

 

All kinds of active/reactive energy meters can be calibrated. 

 

 

Technical Specification

 

 

Range

Capacity

Adjustment 

Degree

Adjustment 

Range

Stability 

Distortion

(linear load)

Measurement 

accuracy

AC Voltage 

 57.7V~380V

30VAmax/

phase

0.01%RG

0~120%RG

 

0.01%RG 

3min CL0.05

0.02%RG 

3min CL0.1

0.2% CL0.05

0.5% CL0.1

±0.05%RG CL0.05

±0.1%RG CL0.1

AC Current 

 0.05A~120A

100VAmax/

phase

@100A

0.01%RG

0~120%RG

 

0.01%RG 

3min CL0.05

0.02%RG

3min CL0.1

0.2% CL0.05

0.5% CL0.1

±0.05%RG CL0.05

±0.1%RG CL0.1

Phase 

0.00°~359.99°

 

0.01°

0.00°-359.99°

0.01°

 

±0.05°

Frequency 

40Hz ~70Hz

 

0.002Hz

40Hz -70Hz

0.002Hz

 

±0.003Hz

Power/Energy

 

 

 

 

 

 

±0.05%RG CL0.05

±0.1%RG CL0.1

pf≥0.5

Output 

Harmonics

2nd to 63rd

Post Buying Request