user login

Voltage Meter / Multimeter Electrical Calibrators With 8 Inch Color Touch Screen

Place of Origin: Zhejiang

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Energy Meter Calibrator, Digital Panel Meters, Multifunction Power Meter

Product Detail

Model No.: AT1013

Product Description

Voltage Meter / Multimeter Electrical Calibrators With 8 Inch Color Touch Screen

 

 

 Main function:

 

AT1013 can calibrate all kinds of Multimeter below Class 0.5, Voltage meter, Ammeter, Ohmmeter, 

and so on. 

 

 

Main features:

 

8 inch color touch screen, interface friendly, easy to operate; 

The outputs of voltage, current and resistance can be adjusted continuously; 

Applied as AC&DC standard sources; 

Equipped with RS-232, AT1013 can support both stand-alone operation and PC control;

Self-protection, alarming and displaying fault location for output overload, Voltage short circuit and 

Current open-circuit;

Automatically detect, diagnose and alarm for failure. 

Remotely updating online, easily achieve software update;

With multifunction, the equipment can calibrate Multimeter, Voltage meter, Ammeter, Ohmmeter;

Output 2nd ~63rd harmonics;

Support calibrating by userself.

 

 

Technical specification: 

 

AC Voltage output:

Range: 2V, 20V, 200V, 700V

Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter

Adjusting resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG

Stability: 0.02%/2min

Distortion: ≤0.2% (Non capacitive load)

Max output load: 25V and upper ranges: 20VA each phase

Accuracy: 0.1%RG 

 

AC Current output:

Range: 2mA, 20mA, 200mA, 2A, 25A;

Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter; 

Adjusting resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG

Stability: 0.02%/2min 

Distortion: ≤0.2% (Non capacitive load);

Max output load: 20VA (20A range); 

Accuracy: 0.1%RG 

 

Frequency Output

Adjusting range: 50Hz, 400Hz;

 

Harmonic setting

Harmonic order: 2nd ~63rd ;

Harmonic amplitude: 0~40%;

Harmonic angle: 0°~359.99°;

Harmonic set error: 2~31times: ≤±0.1%,32~63 times: ≤±0.2%

 

DC Voltage output

Range (4 wires): 200mV, 2V;

Range (2 wires): 20V, 200V, 750V, 1000V; 

Adjusting range: (0~120) %RG; 1000V: (0~100) %RG

Adjusting resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG;

Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)

Output load: ≥50mA;

Accuracy: 0.1%RG;

Ripple content: no more than 1%.  

 

DC Current output

Range: 200μA, 2mA, 20mA, 200mA,2A, 25A;

Adjusting range: (0~120) %RG;

Adjusting resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG;