Place of Origin: | Zhejiang |
---|
Location: | Hangzhou, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Mold Temperature Control Unit, Oil Temperature Control Unit, Water Temperature Control Unit |
Model No.: | KSWc |
---|
Double Compressor Water Cooled Screw Water Chiller Used For Injection Molding Machine
Quick Detail:
Central chilling stations with flexibility and diversity. All in one compact package. Central stations are available in air or water cooled includes integral pump tank, circulation chill water pump, and process pump, multi-circuit water cooled isolated modules, oversized tanks, stainless steel plate evaporators and condensers, cooper nickel condensers are available, non-corrosive wetted components, staged with energy savings features, makup water, Copeland Scroll compressors.
Description:
Independent design of refrigeration system, relatively independent multi-hand piece units, a minimum of moving parts, reliable operation;
Using imported high efficiency semi-hermetic twin-screw compressor with high energy efficiency, reliable operation, and long service life;
The compressor is equipped with a patented exhaust muffler unit low noise operation, to ensure low noise operation of the unit;
Fully packaged with controls and can easily be connected into your existing or new water systems. Contact our application engineering with your specific application. At KASSEL you will get curious prompt service.
Specifications:
Model KSSW | 300L | 360LS | 400LS | 500LS | 600LS | ||
Nominal Refrigeration Capacity | KW | 990 | 1226 | 1428 | 1690 | 2088 | |
Kcal/H(*10^4) | 85.1 | 105.4 | 122.8 | 145.3 | 179.3 | ||
Voltage | 3/N/Peac380v/50hz | ||||||
Compressor | Form | Semi-Hermetic Screw Compressors | |||||
Quantity | 1 Table | 2 Table | 4Table | ||||
Power KW | 191 | 240 | 276 | 330 | 420 | ||
Refrigerants | R22 | ||||||
Refrigeration Doses(Kg) | 246 | 290 | 336 | 390 | 492 | ||
Control Mode | Touch Screen Control Microcomputer | ||||||
Protection Function | Reverse-Phase Leakage Protection, Oil Differential Protection, High And Low Voltage Protection, Water System Fault Protection, Frost Protection, Thermal Overload Protection Compressor, Other | ||||||
Energy Control Section% | 0/33/66/100 | ||||||
Condenser | Form | High Efficient External Screwed Shell And Tube | |||||
In&Outlet Temperature | 30/35 | ||||||
Water Resistance(Kpa) | 60 | ||||||
Water Flow(M³/H) | 250 | 300 | 340 | 390 | 500 | ||
Flange Diameter | Dn150 | Dn150*2 | Dn150*4 | ||||
Evaporator | In&Outlet Temperature | 12/7 | |||||
Water Resistance(Kpa) | <=60 | ||||||
Water Flow(M³/H) | 200 | 245 | 286 | 340 | 418 | ||
Flange Diameter | Dn125 | Dn150 | 95.2 | ||||
Heat Recovery | Heat At 7 (*10^4)Kcal/H | 58.8 | 72.6 | 79.7 | 85.1 | 95.2 | |
Circulating Water | `30-52 | ||||||
Dimension | L(Mm) | 4000 | 4000 | 4000 | 4500 | 5600 | |
W(Mm) | 1450 | 1450 | 1450 | 1450 | 2000 | ||
N(Mm) | 2200 | 2200 | 2200 | 2200 | 2500 | ||
Weight(Kg) | 4500 | 4800 | 5300 | 6500 | 9500 |
Competitive Advantage:
Scientific design and years of engineering experience can help provide you the best scheme of tailor-made ice making system
Modular design makes it is easy and convenient to move and maintain
Quality after-sales service
Reduce the cost and time of installation & dismantlement as much as possible
Strong adaptability and stable quality