Place of Origin: | Zhejiang |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Safety Circuit Breaker, Residual Current Circuit Breaker, 3 Phase Circuit Breaker |
Model No.: | HP9117C 0.7-3KVA |
---|
ABM Technology non critical 1KVA / 900 W 110V UPS with AS400 card for data loss HP9117C
Key Features
Protects against downtime, data loss and process interruption by providing continuous, clean power
Offers premium performance with a 0.9 power factor and >95% efficiency
Increases battery service life and system uptime with ABM battery charging technology
Enables prolonged runtime of essential equipment during power outages by allowing for orderly, remote shutdown of non-critical systems or processes thanks to a capability to control load segments.
Provides installation flexibility with a choice of rack or tower designs, both conserving valuable space
Can replace batteries online, convenient for user to use
Enhanced monitoring and configuration capability through easily navigated multilingual graphical display.
Replace battery online: ABM Technology:
Application
IT and network environment, servers and network devices, telecom, VoIP and security systems, medical systems, diagnosis and medical screening system, Patient record archives, Manufacturing systems, Chip fabrication, Pharmaceutical production, Chemical processing
Follow standard of GB/IEC regulation: EMC:GB7260.2/IEC62040-2 GB/17626.2~5/IEC61000-4-2~5 SAFETY:GB4943
Note: Product specifications are subject to change without further notice
Technical Specifications of Online UPS HP9117C 1-3KVA
Model |
HP9117 1-3KT/1-3KR |
||||||||||||||||
1KT/1KR |
1KT-XL/1KR-XL |
2KT/ |
2KT-XL/ |
3KT/ |
3KT-XL/ |
||||||||||||
Capacity |
1KVA/900 W |
2KVA/1800 W |
3KVA/ |
||||||||||||||
Nominal Voltage |
100/110/120/127VAC or 200 |
||||||||||||||||
Nominal Frequency |
50/60 Hz |
||||||||||||||||
Input |
|||||||||||||||||
Voltage Range |
60-138VAC or 115-276VAC |
||||||||||||||||
Frequency Range |
50HZ:(4654HZ) |
||||||||||||||||
Power Factor |
0.98 |
||||||||||||||||
Output |
|||||||||||||||||
Voltage precision |
100/110/120/127VAC(±2%) |
||||||||||||||||
Frequency precision |
50Hz/60Hz±0.05Hz |
||||||||||||||||
Power Factor |
0.9 |
||||||||||||||||
Harmonic Distortion |
Linear Load3% |
||||||||||||||||
Overload capacity |
overload(110%150%) |
||||||||||||||||
Current Crest Ratio |
31 |
||||||||||||||||
Transfer time |
0ms(AC→DC) |
||||||||||||||||
Battery | |||||||||||||||||
DC voltage |
|