Place of Origin: | Beijing |
---|
Location: | Beijing, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Professional body composition analyzer quantum bio-electric body analyzer
Quick Detail:
Description:
Body Composition Analyzer is designed to calculate regional body composition, empowering health care professionals to better determine health risk associated with visceral and abdominal fat. The BS-BCA2 model is based on the latest statistics method DXA, which analyzes human body composition including fat, weight, BMI (Body Mass Index), none-fat and other health indicators through multi-frequency bio-electrical impedance analysis method, also called MFBIA. It calculates by the built-in high performance computer, and gives out instruction upon the analysis result for testers’ reference as plans to lose weight.
Current has different penetration force depending on frequency. Since low frequency cannot penetrate cells and flow on the external surface’s water, it measures only water content outside cells, while higher frequency means that you can measure even the water content inside cells since it penetrates inside cells, that is, by using diverse frequency, the GS6.6 model can accurately measure water contents inside and outside cells separately. When a body touches an electrode, contact resistance occurs, and it is important to control the contact resistance in order to correctly measure the resistance in a body.
Applications
Segmented body composition analysis
Detect BMI, and other healthy data
Emit healthy report and weight control plan
How does body elements analysis equipment work
Human body elements analysis equipment, applies the accurate measurement of AVR micro computer controller, bases on new statistics method DXA, analysis human elements: fat weight BMI(body mass index), non-fat and other health indicators through multi-frequency bioelectrical impedance analysis melthod(MFBIA). give instruction on guests' health. and provide a scientific basis for losing weight effectively. Which is considered as an epoch-making results of the health industry. If is health consultants, and it provide an independent analysis of health data for each test. Applicable to major fitness, body centers, medical centers, senior clubs, supporting projects of losing weight.
Data function
- Grasp the slimming effect to make the slimming treatment, providing the scientific basis.
- The reasonable ease and weight control help maintain the best physical strength Distinction between muscle type overweight and obesity, find the best control weight method.
- Direct energy intake and dietary intake of nutrients in proportion.
- Guiding take nutrition recovery measures to promote the hard synthesis muscles.
- Evaluation the rehabilitation treatment effect, guiding scientific body slimming with scientific training, rehabilitation, and nutrition.
- Understand and detection teenagers the status of the physical and health, developing their the feasible exercise program.
- Understand the environment, nutrition and other factors on body composition effects.
- Know about the difference of similar others group ingredients.
- As reduce cardiovascular, diabetes and some cancers and other chronic disease incidence of the important preventive measures.
Specifications :
Test Method |
multi-frequency bioelectrical impedance analysis (MFBIA) |
Test Part |
Bio-electrical impedance analysis on the part of left upper limb, right upper limb, trunk, left lower extremity, right lower extremity |
Test Frequency |
three different frequency(20KHz, 50KHz, 100KHz) |
Electrode Method |
8 point contact eletrode |
Computing Method |
do not estimate through empirical value |
Output Value(25) |
TBW, protein, mineral salt, body fat, bone weight, IBW, fat-free weight, SMM(skeletal muscle), BMI(body mass index), PDF(percentage of body fat), WHP(waist-hip ratio), moisture ratio, obesity diagnosis, nutritional assessment, weight assessment, obesity assessment, goal weight, weight control, fat control, muscle control, health assessment, basic metabolism, Bio-electrical impedance |
Rated Current |
less than 180μA |
Power |
input power: AC100V/240V, 50Hz/60Hz |
Screen |
320*240 STN LCD touching screen |
Operation Language |
English and multiple language optional |
Values Storage |
50000*10 and SD card unlimited expansion is available |
External Storage |
SD card transfer to computer for large storage |
External Interfaces |
RJ-45, USB2 |
Printer Interfaces |
USB |
IC Card System |
standard IC card control |
Printer |
A4 color paper ink-jet printer(manufacturers appoint the model), internally installed thermal |
MEAS. of Package |
package: 82*52*32cm(carton No.1) 160*52*47cm(Carton No.2) |
Test Time |
no more than 2 minutes |
Operation Environment |
temperature: 10~400°C(50~1040°F) humidity: 30~80%RH, 500~600hPa |
Conservation Environment |
temperature: 0~400°C(32~1040°F) humidity: 30~80%RH, 500~600hPa |
Test Scope of Weight |
10~200kg test scope of age: 10~99 ages test scope of height: 90~200cm |
External Expansion Project |
ultrasonic height measurer(selective purchasing) |
Machine picture