user login

Adhered Temperature Transducer Current transducers

Min. Order: 1 Piece/Pieces
Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: GPRS GPS Data Logger, GSM RTU GSM SMS Alarm Controller, GSM RTU GSM SMS Temeprature Alarm Controller, GSM RTU GPRS RTU 3G RTU Controller Alarm S26x, GSM RTU

Product Detail

Model No.: TMI300
Output: Analog Sensor
Theory: Resistance Sensor
Usage: Temperature Sensor
Brand Name: King Pigeon
Show

Product Description

 

Water Leakage, Water Oil Overflow, Water Oil Level   Detectors and Tranducers

Model:WLD300              Name: Multi-Level Water Oil   Level Detector

Special for one level or more levels monitoring in the   oil tank or water tank or river and other applications. when the water level   or oil level in the tank higher than or lower than the related float ball,   the high level or middle or low or related sensor will trigger and output an   alarm signal.; DC12V Powered up;  L-M-H   3Levels, 30CM; Output Type: NC or NO (Default is NC). Other Length or Oil   Detection please tell us

Model:WLI100               Name: Immersion hydrostatic   liquid level Transducer

The drop-type hydrostatic level transmitter is used to   measure the liquid level applications. Output of 4-20mA DC. Powered up 24VDC   (12~36VDC is optional), Default depth is 5m. if need other range or liquid   please contact us.

Model:WLV101              Name: Sewage Wastewater Level   Transducer

Special for monitoring and measuring sewage in sewage   facility or sewage treatment plants, output 0~5V. Powered up 9~36VDC,  Default 450mm, range can be from   100mm~2000mm. if need other range please contact us.

Model:WLV102              Name: Diesel   Oil Fuel Water Tank Level Transducer

Special for monitoring and measuring diesel oil, diesel   fuel, and water level in vehicles, power generator, trucks or other tanks.   Output of 0-5V DC. Powered up 9~36VDC. Default 450mm, range can be from   100mm~2000mm. if need other range please contact us.

Temperature, Humidity, Temperature and Humidity   Detectors and Tranducers

Model:THV200               Name: Temperature Humidity   Detector and Transducer

With LCD, can be set temperature and humidity alarm   threshold value, when the ambient temperature or humidity is lower than the   Min. value or higher than the Max. value, the detector will be triggered and   output one dry contact signal and voltage. Rated Power Input 12~24VDC; Measurement Range Temperature: -10~50℃; Humidity:0~100%RH; Output Voltage 2 analog 0~5V for temperature and humidity; 2 Dry Contact(NO, Photoelectric   isolated); 1 for temperature alarm, 1 for humidity alarm.

Model:TMI300               Name: Adhered Temperature   Transducer

Special for monitoring solid surface temperature, like   the galvanic battery. Rated Power Input 12~28VDC;Measurement Range 0~100℃;Output Current 4~20mA.

Model:TMI400               Name: Temperature Transducer

Special for measuring the temperature range from   -200~+1600 ℃ and convert to   4~20mA DC signal output.

Equipment Running Status, Current, Voltage Detectors   and Tranducers

Model:ACS100               Name: Air-Conditioner Starter

Special for automatically switch on the air-conditioner   while power goes on. Rated Power Input 5VDC;Action Delay Time   10Seconds;Output Pulse Time 1Second; Installation Type Inside the   air-conditioner.

Model:LVD100                Name: Low Voltage Status   Detector

Special for monitoring low voltage 2~5V power voltage   status, e.g. Led status, if detected voltage loss then will output a dry   contact alarm signal. Input Voltage:2~5VAC or 2~5VDC,no need external power   source to power on it. Output Type: Dry contact. when the power voltage is   normal, the relay will be opened; When the Power voltage is failure, the   relay will be closed and transmits out an alarm signal.

Model:AID100                 Name: Current Status   Detector

Special for monitoring 0~50A current   status. if detected current normal or loss then will output a TTL alarm   signal.Rated voltage:5VDC;Input Current 0~50A,no need external power source.   Output Type: TTL. when the power current >=250mA, output voltage to GND   will <0.5V; When the power current <=200mA,output voltage to GND will >3V.

Model:AVD800                 Name: 8-Loop AC Power   Voltage Detector

Special for monitoring 8-loop 140~240VAC 50Hz power   voltage status and output dry contact, if detected voltage loss then will   output an alarm signal. Output Type: 8 Dry contact. when the AC power voltage   is normal, the relay will be closed, and the impedance<50Ω;When the AC   Power voltage is failure, the relay will be opened and transmits an alarm   signal to alarm units.

Model:DVV600                 Name: Direct Current Voltage   Transducer

Special for measuring 0~600V direct   current voltage. Rated Power Input 12VDC;Measurement Range 0~600VDC;Output Voltage 0~5V.

Model:CTI100                  Name: Single-phase Current   Transducer

Special for single-phase AC power current measurement.   Rated Power Input Default:12VDC, Optional: 5VDC,15VDC, 24VDC; Input Current   Default:0~30A, Optional: 0~1A, 0~5A, 0~10A;    Output Current 4~20mA.

Model:VTI100                  Name: Single-phase Voltage   Transducer

Special for single-phase AC power voltage measurement.   Rated Power Input Default:12VDC, Optional: 5VDC,15VDC, 24VDC; Input Voltage   Default:0~500VAC, Optional: 0~275VAC; Output Current 4~20mA.

Model:CTI300                  Name: 3-phase Current   Transducer

Special for 3-phase AC power current A,B,C Phase measurement.   Rated Power Input Default:12VDC, Optional: 5VDC,15VDC, 24VDC; Input Current   Default:0~10A, Optional: 0~1A, 0~5A; Output Current 4~20mA.

Model:VTI300                  Name: 3-phase Voltage   Transducer

Special for 3-phase AC power voltage A,B,C Phase measurement.   Rated Power Input Default:12VDC, Optional: 5VDC,15VDC, 24VDC; Input Voltage   Default:0~500VAC, Optional: 0~200VAC; Output Current 4~20mA.


Post Buying Request