Place of Origin: | Zhejiang |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | DC-DC Converters, AC-DC Power Supplies, Medical Power Supply |
Model No.: | YN100-48S12-POC |
---|
DC-DC Converters 100W Output 12V YN100-48S12-POC
Features
Output power: 100W
Wide input range: 36-72VDC
High conversion efficiency: Up to 93%
Line regulation to ±0.5%
Load regulation to ±0.5%
Fixed operating frequency
Isolation Voltage :1,500V
Enable (On/Off) Control
Output over-load protection
Hiccup mode short circuit protection
Over-temperature protection
Input under-voltage lock-out
Output voltage trim: ±10% Vout
Package: Open Frame
Quarter Brick: 2.2×1.37×0.42in
55.9×34.8×10.7mm
Product Overview
These DC-DC converter modules use advanced power
processing, control and packaging technologies to provide
the performance, flexibility, reliability and cost effectiveness
of a mature power component. High frequency Active Clamp
switching provides high power density with low noise and
high efficiency.
Product’s Introduction
The YN100 series is an independently regulated single output converter that uses the industry standard quarter brick package size. The very high efficiency is a result of ENARGY CORP patented topology that uses synchronous rectification and an innovative construction design to minimize heat dissipation and allow extremely high power densities. The power dissipated by the converter is so low that a heat sink is not required, which saves cost, weight, height, and application effort. All of the power and control components are mounted to the multi-layer PCB substrate with highyield surface mount technology, resulting in a more reliable product.
1. Electric Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and base plate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the base plate.
1.1 Absolute maximum ratings
Parameter |
Min |
Typ |
Max |
Units |
Notes |
Input Voltage |
|
|
|
78 |
Continuous, non-operating |
|
|
|
75 |
Continuous, operating |
|
|
|
|
78 |
Operating transient protection |
|
Isolation voltage |
|
|
|
2000 |
In to outBasic insulation, Pollution Degree 2 |
Operating Temperature |
-55 |
|
|
100 |
M-Grade |
Storage Temperature |
-65 |
|
|
125 |
M-Grade |
Enable to –Vin Voltage |
-0.8 |
|
|
10 |
|
1.2 Input Characteristics
Parameter |
Min |
Typ |
Max |
Units |
Notes |
Operating input voltage |
36 |
48 |
72 |
Vdc |
Continuous |
Input Surge Withstand |
|
|
78 |
Vdc |
<100mS |
Under-Voltage Lockout |
|
35.5 |
35.8 |
Vdc |
Turn - On Threshold |
32.5 |
34.0 |
|
Vdc |
Turn - Off Threshold |
|
Maximum Input Current |
|
|
3.3 |
A |
Full Load; Minimum Vdc Input |
Efficiency |
|
92 |
|
% |