user login

50 - 100V DC Three phase EMI Line Filter 20A Isolation voltage 1500V dc

Place of Origin: Zhejiang

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: DC-DC Converters, AC-DC Power Supplies, Medical Power Supply

Product Detail

Model No.: EM-FICM20A

Product Description

Ripple Attenuator Module  MAX Output Current 20A  EM-FICM20A

 

Key Features

MAX.Output Current: 20A

Wide input range: 50-100VDC

High conversion efficiency: Up to 99%

 

Product Overview

These EMI Filter use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency switching provides high power density with low noise and high efficiency.

 

Electric Characteristics

Electrical characteristics apply over the full operating range of input voltage, output load and base plate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the base plate.

 

Absolute maximum ratings

Parameter

Min

Typ

Max

Units

Notes

Input Voltage

50

 

100

Vdc

Continuous, operating

Isolation voltage

 

 

1500

Vdc

Input-- metal shell

 

 

1500

Vdc

output--metal shell

Operating Temperature

-55

 

100

 

Storage Temperature

-65

 

125

 

 

Input Characteristics

Parameter

Min

Typ

Max

Units

Notes

Input voltage range

50

 

100

Vdc

Continuous

Maximum Input Current

0

 

20

A

Full load, Min. input

 

Output Characteristics

Parameter

Min

Typ

Max

Units

Notes

Output Voltage Range

49

 

100

Vdc

 

Output Current Range

0

 

20

A

 

Efficiency

95

 

99.5

%

 

Voltage difference for input-output

0.1

 

1.0

Vdc

 

Attenuation frequency range

0.1

 

100

MHz

 

Attenuation ability

 

52

 

dB

 

 

Isolation Characteristics

Parameter

Min

Typ

Max

Units

Notes

Isolation Voltage

1,500

 

 

Vdc

Input to case

1,500

 

 

Vdc

Output to case

Isolation Resistance

 

100

 

At 500VDC to test it when atmospheric pressure and R.H. is 90%

 

 General Characteristics