user login

BTS-5V6A battery testing equipment for Cylindrical battery Polymer battery

1.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB,CFR,CIF,EXW
Payment Terms: T/T, WU
Supply Ability: 1000
Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Battery Testing System

Product Detail

Means of Transport: Ocean, Air
Type: Lithium
Certification: CE
Usage: Mobile Phone
Brand Name: Neware
Frequency: 10HZ
Packing: wooden
Channel: 8
Production Capacity: 1000
Packing: wooden case
Delivery Date: 30days
Show

Product Description


High precision Battery Test Systems CT-4008-5V6A is a CE certified 8 channel battery analyzer for Li-ion, LiFePO3, Ni-MH, Ni-Cd, and Lead acid battery packs with up to 5V and 10A per channel. The system provides most applications in battery testing fields such as battery performance test, small-scale battery formation, capability grading, battery pack testing, etc. This battery analyzer is designed according to the international standard: each channel has an independent constant-current source and a hardware constant-voltage source. Constant-current source and constant-voltage source can be programmed and controlled by user. With plug-and-play module design, user can freely remove and add module units without interrupting other units.


High precision Battery Test Systems Specifications :

Description

Product Specification

AC Input

AC 110V±10% 50Hz

 Power 

448000 

mW

Resolution

AD: 16bit; DA: 12bit

Input Impedance 

≥1MΩ

Voltage

Measuring Range 

Charge: 25mV~5V

Discharge:25mV~5V

 Discharge  Min Voltage

2.5V

Accuracy

± 0.05% of  FS

Stability

± 0.05% of  FS

Current

Range

Charge: 30mA~6000mA             Discharge: 30mA~6000mA

Accuracy

± 0.1% of  FS

Stability

± 0.1% of  FS

Power

Output Power Per Channel

30W

Stability

± 0.2% of  FS

Time

Rise Time

 20ms (0~Full Range)

Step Time

≤ (365*24)  hour/step

Time Format 00:00:00 (h:min:s)

Data Acquisition

Intervals

Time interval Δt:(1s~60000s)

Voltage interval ΔU: (25mV~5V)

Current interval ΔI: (30mA~6000mA)

Frequency

10Hz

Charge

Modeof Operation 

CCC, CVC, CC & CVC

End Conditions

Voltage, Current, Test Time, Capacity

Discharge

Modeof Operation 

CCD, CPD

End Conditions

Voltage, Current, Test Time, Capacity

Our advantages:

 

1.Reasonable Price, standarbale and Reliable Product.

2.Improve the quality and life expectancy of your products

3.Work Performance more effective and efficacy

4.16years innovation guarantees you a in better future.

Ni-MH battery charge station

Ni-MH battery charge stationNi-MH battery charge stationNi-MH battery charge stationNi-MH battery charge station

 

Post Buying Request