Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB,CFR,CIF,EXW |
Payment Terms: | T/T |
Supply Ability: | 1000 |
Place of Origin: | Guangdong |
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Battery Testing System |
Type: | Lithium |
---|---|
Certification: | CE |
Usage: | Mobile Phone |
Brand Name: | NEWARE |
steels product: | steels |
Warranty: | 1 year free warranty |
Production Capacity: | 1000 |
Packing: | Standard |
Delivery Date: | 30 |
5V50mA battery charge and discharge testing system
Test Items: cuttent, voltage, DCIR, Pulse Test, HPPC, Rate, Static capacity, cycle life and etc.
Type of battery test:Li-ion, LifePO4, Ni-MH, Ni-Cd, Lead acid , battery pack, EV/PHEV battery etc.
Similar Models: 5V1mA, 2mA, 5mA, 10mA, 20mA, 100mA, 5V6A(double range, 5V100mA & 5V6A)
This small range testing system all mainly used in universities, research institute, and company labs for coin cell material research or cycle test.
Different Specifications could be customized, Ranging from 1mA-3000A, 5-800V;
Our customers come from Samsung, LG, BYD, SAFT, University of oxford, University of Stanford, University of Wollongong, etc. making us one of the top companies in this area.
BTS-5V50mA Specification Sheets
Battery testing sysem Description | Battery testing sysem Product Specification | ||||
AC Input | AC 110V±10% 50Hz | ||||
Power | 354 | mW | |||
Resolution | AD: 16bit; DA: 16bit | ||||
Input Impedance | ≥1MΩ | ||||
Voltage | Measuring Range | Charge: 10mV~5V | Discharge: 10mV~5V | ||
Discharge Min Voltage | 10mV | ||||
Accuracy | ± 0.1% of FS | ||||
Stability | ± 0.1% of FS | ||||
Current | Range | Charge: 0.25mA~50mA Discharge: 0.25mA~50mA | |||
Accuracy | ± 0.1% of FS | ||||
Stability | ± 0.1% of FS | ||||
Power | Output Power Per Channel | 25mW | |||
Stability | ± 0.2% of FS | ||||
Time | Rise Time | 20ms (0~Full Range) | |||
Step Time | ≤ (365*24) hour/step | Time Format 00:00:00 (h:min:s) | |||
Data Acquisition | Intervals | Time interval Δt:(1s~60000s) | |||
Voltage interval ΔU: (10mV~5V) | |||||
Current interval ΔI: (0.01mA~5mA) | |||||
Frequency | 10Hz | ||||
Charge | Modeof Operation | CCC, CVC, CC & CVC,CPC,CC&CCC | |||
End Conditions | Voltage, Current, Test Time, Capacity, -△V | ||||
Discharge | Modeof Operation | CCD, CPD | |||
End Conditions | Voltage, Current, Test Time, Capacity, -△V | ||||
Pulse | charge | CCC ,Constant power mode | |||
Discharge | CCD,Constant power mode | ||||
Min Pulse Width | 500ms | ||||
Automated Switch | Automated swith from charge to discharge for each pulse | ||||
End Condition | Voltage, Test Time | ||||
DCIR testing | Support DCIR testing | ||||
Cycle | Loop Measure Range | 1~65535 times |
The data can be exported to EXCLE and PDF with data and curve.