Battery charging station for Power Station IGBT-750V300A specification :


Project index

Parameter index

Input Power

AC 380V ±10% / 50Hz

Output Power

225KW

Input Current

380A/Each Phase

Input Power

250KW

Voltage

Per Channel Voltage Range

75V~750V

Discharge Min Voltage

75V

Accuracy

± 0.2% of FS

Stability

± 0.2% of FS

Current

Per Channel Current Range

1.5A~300A

Accuracy

± 0.2% of FS

Stability

± 0.2% of FS

Constant voltage cut-off current

0.6A

Power

Per Channel Output Power 

30KW

Stability

± 0.4% of FS

Time

Current Response Time 

Maximum current rise time of 100ms (10% ~90% )

Step Time Range 

≤(365*24 )hour/step,

Time Form Support 00:00:00(h,min:s,ms)

Data Recording

Record Condition

Lower sampling time:100ms

Lower sampling Voltage:1.5V

Lower sampling Current:0.6A

Record Frequency 

10Hz

Charge

Charge Mode 

Constant Current Charge,Constant Voltage Charge,

Constant Current and Constant Voltage Charge,CPC

End Conditon

Voltage,Current,Relative Time,Capacity,-ΔV

Discharge

Discharge Mode

CCD,CPD,CRD

End Condition

Voltage,Current,Relative Time,Capacity,-ΔV

Simulation working condition

Charge Model 

Current, Voltage 

Discharge Model

Current, Voltage 

End Condition

Time , Line number

Charge and discharge Continuous switching 

A simulation step can be continuous switching from charge to discharge. 

Simulation file rows limited 

10  thousand

Cycle

Loop Measure Range

1~65535 times

Max Steps Per Loop 

254

Nested Loop

Nested loop Function,Max Support 3 Layers

Auxiliary Channel

Auxiliary Channel type

Temperature, voltage 

Temperature Range

﹣25℃~110℃

Temperature Stability

±2℃

Temperature Resolution 

0.1℃

Voltage Range 

0.5V~5V

Voltage stability 

±(0.05% of reading  + 0.05% of range )

Protection

Software Protection

l Power-down Data Protection

l Off-line Testing Function

l Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time

Hardware Protection

Additional Anti-reverse Protection Model

Channel characteristic

Constant current and Constant voltage use teh double-loop control structure. 

Engyer Regenerative

Can be Regenerative engyer back to the power network

Channle control model 

Independent control

Noise

<85dB

Database

MySQL Database 

A Means of Communication of Upper Machine 

TCP/IP Protoc

Data Output 

EXCEL2010,2013,TXT,Graph

Communication Interface

Ethernet Port

Server hard disk configure

500GB

Server operation system

WindowsXP, Windows 7

Per Unit Main Channels No.

1

Dimensions

EVT,1350*733*1800(mm)

Packing dimensions 

1400*800*1950

Weight 

500KG

Characterized with IGBT, reversible AC/DC converter and CAN supported, our EVTS 7000 brings you higher energy efficiency, smaller space and much convenient to utilize the existing gauge integrated in BMS/BMU.


Our auxiliary single voltage sensors will help you capture the voltages of every single cell in series. this will largely increase the testing safety. You can have an advanced control based on the captured values.


 Feature:                                                                                                       Applications:


1 Resolution: AD: 16bit;DA: 16bit;                                                                1 Driving Cycle Simulation;

2 Accuracy: 0.1% FS;                                                                                      2 Pulse Test / HPPC;

3 Response Time: ≤10ms(Current in the range 10%~90% FS);            3 Rate, Static Capacity, Cycle Life and etc;

4 Output power: Max. 21KVA(user-definable);

5 Data Acquisition frequency: 10Hz; 

6 Minimum pulse width: 500ms;


NEWARE Exhibition:

Battery charging station for Power station Battery charging station for Power station

NEWARE Software:

Battery charging station for Power station Battery charging station for Power station


NEWARE customer: 

Battery charging station for Power station


NEWARE Supplier:

Battery charging station for Power station


Our advantages:

 

All kinds of types are manufactured for a range of current from 1mA to 1000A, a range of voltage from 5V to 500V to meet customers' special needs. We also provide the BTS  which can test the voltage of 0 V or even lower. 

 

1.Reasonable Price, standarbale and Reliable Product.

2.Improve the quality and life expectancy of your products

3.Work Performance more effective and efficacy

4.17years innovation guarantees you a in better future.

 

Warranty and Customer Service:

Neware warrants its equipment for 1 year from shipment, to be free from defects in workmanship and material. For some other consumptive materials, like battery clamps, we provide a 3-month warranty. This warranty, including customer service support and software licenses, is not transferable. Meanwhile, we provide lifetime software update

service to help your equipment optimized in its best status.

 

We provide below customer services:

1.Free Technical Training.

2.Free Service Call Service.

3.Testing Service.

4.Calibration Service.



Post Buying Request