user login

Digital Glass X-ray tubes / ReplacementCEI OCX/65-G X-raytube for Dental Equipment

Place of Origin: Zhejiang

Company Profile

Location: Hangzhou, Zhejiang, China (Mainland)
Business Type: Manufacturer
Main Products: Dental X-ray Tube, Medical X-ray Tubes, Diagnostic X-ray Tube

Product Detail

Model No.: KL2-0.8-70G

Product Description

 

 

Digital Glass X-ray tubes / Replacement CEI OCX/65-G X-ray tube for Dental Equipment

 

 

Quick Detail:

 

Type:Station anode x-ray tube

Application: For intra-oral dental x-ray unit

Model: KL2-0.8-70G

Equivalent to CEI OCX/65-G

Integrated high quality glass tube

 

Description:

 

KL2-0.8-70G Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit. And it is a grid-control tube.

The integrated high quality tube with glass design has one super imposed focal spot and a

reinforced anode. It is extremely important to observe the connection diagram and the grid-resistor value. Any change could modify the dimensions of the focal spot, also varying diagnostic performances or overloading anode target.

The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

 

Applications:

 

KL2-0.8-70G Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

 

Specifications:

 

Nominal Tube Voltage……………………………………..….………..…….…………..…70Kv

Nominal Inverse Voltage…………………………………..…..…….…..………………….85kV

Nominal Tube Current………..……………………..….……….………………………...…8mA

Maximum Exposure Times………………………………………….……….……........ …...3.2s

Maximun anode cooling Rate………………………………………………………………210W

Max. Anode Heat Content………….……….…………………..……………………..…...7.5kJ

Filament Characteristics…………………………………………..Uf=4.0V(Fixed),If=2.8±0.3A

Focal spot ..…………………………………………………….……….….0.8(IEC 60336 2005)

                                 At 70kV 8mA with 5kΩ to 25 kΩbias resister(Fixed)

Grid Resistance Value…………………………recommended by manufacturer for any tube

Target Angle……………………………………………………………….………………..…19°

Target Material………………………………………………………………….………..Tungsten

Cathode type……………………….…………………………………………….…….W filament

Permanent Filtration………..…………..……………...Min. 0.5mmAl/50 kV(IEC60522/1999)

Dimensions………………………………..…………….……80mm length by 30mm diameter

Weight…………………………………………………………………………….…….125 grams

 

 

Competitive Advantage:

 

Elevated anode heat storage capacity and cooling

Constant high dose yield

Excellent life time

 

Post Buying Request